Related Experiment Video
Updated: Feb 1, 2026

The Superficial Inferior Epigastric Artery Fascia Flap for Nerve Reconstruction in Rabbits
Published on: June 13, 2025
Composite Antropyloric Valve and Gluteus Maximus Muscle Wrap for Neoanal Reconstruction: Initial Results
Abhijit Chandra1, Brijesh Mishra2, Saket Kumar1
1Department of Surgical Gastroenterology, King George's Medical University, Lucknow, Uttar Pradesh, India.
Background:
Severe fecal incontinence has a significant negative impact on patient well-being. Current surgical methods of total anorectal reconstruction to substitute a colostomy have suboptimal results. A composite graft using antropyloric valve transposition and gracilis wrap has been described with good outcomes. However, this procedure requires extensive training of patients. Gluteus maximus, an accessory muscle for continence, may be better suited for this purpose.
Objective:
The purpose of this study was to evaluate the outcomes of composite antropylorus-gluteus graft for intractable fecal incontinence.
Design:
Patients underwent a 3-stage procedure: antropyloric transposition with diversion stoma followed by gluteus wrap. Stoma was closed after ensuring the anatomic and functional integrity of the graft.
Settings:
This study was conducted at a single tertiary care institution.
Patients:
Patients who were on permanent colostomy for intractable incontinence or would have had one after abdominoperineal resection were included.
Main Outcome Measures:
Endoultrasonography, MRI, loopogram, saline holding test, anal manometry, St. Mark's fecal incontinence score, and personal interviews were used for measurement.
Results:
Eleven patients underwent the procedure with a median follow-up of 16 months (range, 13-34 mo). Digital rectal examination revealed a resting tone with a distinct squeeze provided by the composite graft. Radiological imaging confirmed healthy grafts. There was a significant improvement in mean anal manometry values (resting pressure: preoperative = 10.25 mm Hg vs postoperative = 20.45 mm Hg; squeeze pressure: preoperative = 22.63 mm Hg vs postoperative = 105.18 mm Hg) and mean incontinence score postprocedure (preoperative = 22.8 vs postoperative = 8.6). On personal interview, majority of the patients were continent and expressed satisfaction with the procedure.
Limitations:
The study was limited by its small sample size with no control group.
Conclusions:
Composite graft in patients with intractable fecal incontinence can serve as a viable novel method for total anorectal reconstruction. However, it should only be recommended for a highly select group of individuals in a surveillance setting. Its long-term outcomes remain to be determined as well as its risk versus benefit.
More Related Videos
06:26Experimental Implementation of a New Composite Fabrication Method: Exposing Bare Fibers on the Composite Surface by the Soft Layer Method
Published on: October 6, 2017
08:36Semi-automated Analysis of Mouse Skeletal Muscle Morphology and Fiber-type Composition
Published on: August 31, 2017
Related Concept Videos
Initiation of Translation
First, the initiator tRNA must be selected from the pool of elongator tRNAs by eukaryotic initiation factor 2 (eIF2). The initiator tRNA (Met-tRNAi) has conserved sequence elements including modified bases at...
Initiation of Translation
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Transcription Initiation
The promoters and enhancers and their accessory proteins allow tight regulation of...
Composite Bodies
Composite bodies have widespread applications in mechanical engineering, from automobiles to aircraft to rockets. For example, an automobile wheel comprises...