Comparison of four staining methods for detecting eosinophils in nasal polyps
Yu Song1, Jinshu Yin2,3, Hong Chang4
1Peking University Ninth School of Clinical Medicine, Beijing, 100038, China.
Abstract:
The study aimed to find a more appropriate method to detect eosinophils in formalin- fixed nasal polyps, since there is no consensus on the standard counting method of eosinophils now. Four 5 μm serial sections were obtained from each 10% neutral formalin-fixed paraffin block and were stained with Chromotrope 2R, Congo red, MBPmAb immunohistochemistry, and conventional hematoxylin and eosin stain respectively. Each section was scanned by the Aperio digital section scanner. The same selected areas were procured for assessment in the serial sections. Chromotrope 2R and MBPmAb immunohistochemistry were specific in detecting eosinophils, which had the lower background staining compared with Congo red and conventional hematoxylin and eosin stain. There were significant differences among the four methods in terms of the eosinophil counting data (p < 0.05), while no significant difference between Chromotrope 2R and Congo red (P = 0.1413). The eosinophil counts in nasal polyps could be more accurately assessed by Chromotrope 2R and Congo red compared with MBPmAb immunohistochemistry and conventional hematoxylin and eosin stain. The popularization of Chromotrope 2R and Congo red may help to unify the eosinophil count in the definition of eosinophilic CRSwNP.
Related Concept Videos
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Nose and Nasal Cavity
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...