The use of a string with a stent for self-removal following ureteroscopy: A safe practice to remain
Karen M Doersch1, Amr Elmekresh2, G Luke Machen2
1MD/PhD Program, Texas A&M Health Sciences Center, Temple, TX, USA.
Abstract Objectives:
To examine the safety and effectiveness of the use of a stent with a string attached after ureteroscopy (URS) for self-removal of the stent by the patient.
Patients And Methods:
After Institutional Review Board approval, a retrospective chart review was performed concerning patients who underwent URS and received an indwelling stent with or without a string attached to the stent (94 vs 349, respectively). Amongst the string group patients received a single- or a double-arm-stringed stent (31 vs 63, respectively). Statistical analyses included chi-squared and Student's t-tests.
Results:
The string group consisted of 94 procedures, in which 59.6% of the patients were male with a mean (SD) age of 50.0 (16.5) years. In the no-string group, 51.3% of the 349 procedures were performed in males and the mean (SD) age was 54.9 (18.1) years. Complication rates were 12.8% in the string group and 14.0% in the no-string group (P = 0.867). In the string group, 17.0% of the patients returned to the Emergency Department, whilst 15.8% of the no-string patients returned (P = 0.753). The complication rate in the single- and double-arm groups were 12.9% and 12.7%, respectively (P > 0.910). Self-removal of stents was successful in 94.7% of patients (89/94).
Conclusions:
The use of a stent with a string after URS appears safe and effective. Few patients had difficulty removing their stents and complication rates were similar in the groups with and without a string attached to their stents. Single- and double-arm-stringed stents have similar complication rates.
Related Concept Videos
Problem-Solving: Tuning of a Guitar String
The string's wave speed can be regulated by varying the linear density. Tension is the other property that determines the speed of...
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security:
Characteristics of Practical Op Amps
The ratio of differential gain to the common-mode gain is defined as the common-mode rejection ratio (CMRR). This ratio quantifies the ability of operational amplifiers (op-amps) to reject common-mode...
Theoretical Foundations of Nursing Practice
Theories provide a perspective to assess patients' conditions and organize data and methods. They also assist in analyzing and interpreting information. They represent a...
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
Design Example: Calculating Safe Diameter for Wind-Exposed Disc