Cement Augmentation of Dynamic Hip Screw to Prevent Screw Cut Out in Osteoporotic Patients with Intertrochanteric
Avinash Kumar Rai1, Rajesh Goel1, Chirag Bhatia1
1Department of Orthopaedics, Government Medical College, Kota, India.
Purpose:
The purpose of this study is to describe a method of inserting cement in the femoral head before fixation with dynamic hip screw to prevent screw cut out due to osteoporosis and to evaluate its clinical outcome in these patients.
Materials And Methods:
In this prospective study, 30 patients aged 60 years and older with intertrochanteric fracture were included. Bone mineral density was measured. After reaming of the femoral head and neck with a triple reamer and polymethyl methacrylate, bone cement was introduced into the femoral head using a customized nozzle and a barrel fitted on a cement gun. A Richard screw was inserted and the plate was fixed over the femoral shaft. Patients were mobilized and clinical outcomes were rated using the Salvati and Wilson's scoring system.
Results:
More patients included in this study were between 66 and 70 years old than any other age group. The most common fracture according to the Orthopaedic Trauma Association classification was type 31A2.2 (46.7%). The T-score was found to be -2.506±0.22 (mean±standard deviation); all patients were within the range of -2.0 to -2.8. The duration of radiological union was 13.67±1.77 weeks. Salvati and Wilson's scoring at 12 months of follow up was 30.96±4.97. The majority of patients were able to perform their normal routine activities; none experienced implant failure or screw cut out.
Conclusion:
Bone cement augmentation may effectively prevent osteoporosis-related hardware complications like screw cut out in elderly patients experiencing intertrochanteric fractures.
More Related Videos
06:58Method and Instrumented Fixture for Femoral Fracture Testing in a Sideways Fall-on-the-Hip Position
Published on: August 17, 2017
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Related Concept Videos
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Hydration of Cement
Soundness of Cement
Portland Cement