Computed tomography pulmonary angiography and venography with a low dose of contrast medium
Jun Nakane1, Norinari Honda2, Kazuhiro Tsuchiya3
1Radiology Service, Saitama Medical Center, Saitama Medical University, 1981 Kamoda, Kawagoe, Saitama, 350-8550, Japan. jun_n@saitama-med.ac.jp.
Abstract:
The authors developed a method to ensure sufficient opacification of pulmonary vasculature for separate depiction of arteries and veins in three-dimensional form with a small dose of contrast medium utilizing a test injection to determine optimal timing of computed tomography (CT) scanning. The dose was determined by a simulation based on a pharmacokinetic model. The contrast medium was administered at a rate of 5.0 mL/s for 3 s, followed by helical scanning at the timing determined by a dynamic CT scanning following the test injection. Images of 20 consecutive patients acquired with a 64-row CT scanner were evaluated. Quality of vessel depiction was assessed on the basis of the following: HU values at the main pulmonary artery (MPA) and left atrium (LA), distance between the pleural surface and the distal end of the pulmonary vessels on three-dimensional CT pulmonary arteriography and venography (3D-CTPAV), and subjective visual assessment of quality of the 3D-CTPAV images. Time to generate the 3D-CTPAV images was recorded. The mean ± standard deviation (SD) of the HU values at MPA/LA and the distances to the pleural surface for pulmonary arteries/veins were 448.0 ± 123.1/277.3 ± 60.85 HU and 9.21 ± 3.60/10.7 ± 5.45 mm, respectively. The image quality was visually rated as excellent for all of the patients. The mean time ± SD to generate 3D-CTPAV images was 13.6 ± 6.7 min. In conclusion, three-dimensional images of the pulmonary vasculature can be created using 21 mL (including 6 mL for the test injection) of contrast medium.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...