Related Experiment Video
Updated: Feb 1, 2026

Murine Renal Transplantation Procedure
Published on: July 10, 2009
Time-intensity curve analysis of contrast-enhanced ultrasound is unable to differentiate renal dysfunction in the
Nordeval Cavalcante Araújo1,2, José Hermógenes Rocco Suassuna3
1University of the State of Rio de Janeiro, Rio de Janeiro, Brasil. nordeval@oi.com.br.
Background:
Contrast enhanced ultrasonography (CEUS) assessment of kidney allografts mainly focuses on graft rejection. However, studies on delayed graft function (DGF) without acute rejection are still lacking. The aim of this study was to build a time-intensity curve (TIC) using CEUS in non-immunological DGF to understand the utility of CEUS in early transplantation.
Methods:
Twenty-eight patients in the short-term postoperative period (<14 days) were divided according to the need for dialysis (early graft function [EGF] and [DGF]) and 37 subjects with longer than 90 days follow-up were divided into creatinine tertiles. Time to peak [TTP] and rising time [RT were compared between groups.
Results:
EGF and DGF were similar, except for creatinine. In comparison to the late group, medullary TTP and RT were shorter in the early group as well as the delay regarding contrast arrival in the medulla (in relation to cortex) and reaching the medullary peak (in relation to artery and cortex). In the late group, patients with renal dysfunction showed shorter temporal difference to reach medullary peak in relation to artery and cortex.
Conclusions:
Although it was not possible to differentiate EGF and DGF using TIC, differences between early and late groups point to blood shunting in renal dysfunction.
More Related Videos
06:38Early Detection of Drug-Induced Renal Hemodynamic Dysfunction Using Sonographic Technology in Rats
Published on: March 11, 2016
06:20Contrast-Enhanced Subharmonic Aided Pressure Estimation SHAPE Using Ultrasound Imaging with a Focus on Identifying Portal Hypertension
Published on: December 5, 2020
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Precipitation Titration Curve: Analysis
Bending of Curved Members - Strain Analysis
The important part of bending analysis for such a member...
Sieve Analysis and Grading Curves
The Periodic Table
Periodic Classification of the Elements