Related Experiment Video
Updated: Feb 1, 2026

Rat Model of Adhesive Capsulitis of the Shoulder
Published on: September 28, 2018
Adhesions on polypropylene versus Sepramesh® meshes: an experimental study in rats
Maria de Lourdes Pessole Biondo-Simões1, Victor Cezar de Azevedo Pessini1, Pedro Henrique Caldeira Porto1
1Universidade Federal do Paraná, Departamento de Cirurgia, Curitiba, PR, Brasil.
Objective:
to compare the formation of induced intraperitoneal adhesions in rats when using polypropylene and Sepramesh® meshes.
Methods:
we used 20 male Wistar rats, randomly grouped in two groups of ten animals each. We arranged two 10x20mm meshes intraperitoneally into each animal, one being the polypropylene (PP), and the other, Sepramesh®. In Group 1, the polypropylene mesh was positioned to the right, and the Sepramesh®, to the left. In Group 2, the meshes' layout was reversed. After 14 days of the procedure, we euthanized the animals and analyzed the incorporation and percentages of adhesions macroscopically in each mesh. We submitted the collected data to statistical analysis with a significance level of 5% (p<0.05).
Results:
all meshes showed adhesions. In the Sepramesh® ones, the percentage of surface covered by adhesions ranged from 2% to 86%, with a mean of 18.6±18.6%, while in the polypropylene meshes, it varied between 6% and 86%, with an average of 57.4%±34.9% (p<0.05). The preferred adhesion sites on both meshes were the edges.
Conclusion:
although no mesh was able to completely inhibit the development of adhesions, the Sepramesh® mesh presented less adhesions to the polypropylene mesh. The most common sites of adhesion formation were the edges of the prosthesis, which evidences the importance of the adequate fixation of the meshes.
Related Concept Videos
Adhesion
Capillary action is a result of water’s adhesive tendencies. When a narrow...
Mesh Analysis
A fundamental concept in mesh analysis is the definition of meshes and mesh currents. A mesh is a closed...
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Mesh Analysis for AC Circuits
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
Cell Adhesion in Plants
Pectins are complex heteropolymers mainly composed of negatively-charged α-D-glucopyranosyl uronic acid and some neutral glycosyl residues such as α-L-rhamnopyranose, α-L-arabinofuranose,...
Immunoglobulin-like Cell Adhesion Molecules
Ig-CAMs exhibit either homophilic binding (to other Ig-CAMs) or heterophilic binding (to other ligands such as integrins). While most Ig-CAMs...

