A Minimally Invasive Approach for Placing Sew-On Epicardial Leads in the Child
Joseph R Nellis, Zachary W Fitch, Ashley Y Choi
1Pediatric & Congenital Heart Center, Duke Children's Hospital, Durham, NC USA.
Abstract:
Traditionally, pacing leads are placed transvenously, although smaller pediatric patients who require permanent pacemakers may benefit from delaying tranvenous lead placement until they are larger. Alternative, minimally invasive atrioventricular pacing options have not previously existed for this patient population, leaving many of these children with large sternotomies or thoracotomies. Using three port sites and an adjustable shaft dual-needle suturing device, we placed a steroid-eluting, sew-on epicardial lead on the right atrium of a 9-year-old patient. This is one of the earliest reported cases of a minimally invasive technique for sew-on epicardial lead placement on the atrium of a child. Although based on a single case, we believe that this approach is safe, reliable, and reproducible and that it can be used to place leads on any aspect of the heart. Adoption of this technique will allow for earlier atrioventricular pacing, which may decrease the incidence of pacemaker syndrome, and thus improve overall outcomes in this patient population.
More Related Videos
Related Concept Videos
Placing Concrete
While placing concrete, care is taken to ensure that the concrete is laid in uniform layers, and hand shoveling and moving concrete using poker vibrators is avoided. Also,...
Phase-lead and Phase-lag Controllers
Frustration and Conflict: Approach-Approach, Approach-Avoidance
One common type of conflict is the Approach–Approach Conflict. In this case, a person faces two desirable...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Actuarial Approach
Consider the example of a high-risk surgical procedure with significant early-stage mortality. A two-year clinical study is conducted,...