Comparison of Pipeline Embolization Device and Flow Re-Direction Endoluminal Device Flow Diverters for Internal
Christoph J Griessenauer1,2, Ajith J Thomas3, Alejandro Enriquez-Marulanda3
1Department of Neurosurgery, Geisinger, Danville, Pennsylvania.
Background:
Flow diversion has become an accepted endovascular treatment modality for intracranial aneurysms. Studies comparing different types of flow diverters are currently lacking.
Objective:
To perform a propensity score-matched cohort study comparing the Pipeline Embolization Device (PED; Medtronic, Dublin, Ireland) and Flow Redirection Endoluminal Device (FRED; MicroVention, Aliso Viejo, California).
Methods:
Aneurysms of the internal carotid artery proximal to the communicating segment treated with PED at 2 neurovascular centers in the United States were matched with aneurysms treated in the European FRED study using propensity scoring. Aneurysms treated in the setting of subarachnoid hemorrhage were excluded from matching. Occlusion rates and complications were evaluated.
Results:
Two hundred twenty-one internal carotid artery aneurysms were treated with PED and 282 with FRED. Propensity score matching controlling for age, sex, aneurysm size, location, number of flow diverters, and adjunctive coiling resulted in 55 matched pairs. Median angiographic follow-up was nonsignificantly longer for FRED compared to PED (12.2 vs 7.5 mo, P = .28). The rate of complete occlusion did not differ between flow diverters (80% vs 80%, P > .99). Functional outcome and complications were comparable for PED and FRED.
Conclusion:
Propensity score-matched analysis of PED and FRED for internal carotid artery aneurysms revealed comparable angiographic complete occlusion and complication rates. Whether FRED has an advantage in terms of near complete aneurysm occlusion warrants further investigation. Limitations include the retrospective design and lack of an independent assessment of radiographic outcome in a core-laboratory and functional outcomes, among others, and the results should be interpreted as such.
Related Concept Videos
Non-ohmic Devices
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
Mnemonic Devices
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...
Gene Flow
Flow Cytometry
In...
Flow Sheet
Here's a closer look at the examples of flowsheets commonly used by nurses:
Graphic Sheet Documentation:
Flow Table Test
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...


