Related Experiment Video
Updated: Feb 1, 2026

Green Fluorescent Protein-based Expression Screening of Membrane Proteins in Escherichia coli
Published on: January 6, 2015
HflX protein protects Escherichia coli from manganese stress
Sandeepan Sengupta1, Avisek Mondal, Dipak Dutta
1Department of Biochemistry, Bose Institute, P-1/12, C.I.T. Scheme VIIM, Kolkata 700 054, India.
Abstract:
The ribosome-binding GTPase HflX is required for manganese homeostasis in E. coli. While under normal conditions ΔhflX cells behave like wild type E. coli with respect to growth pattern and morphology, deletion of hflX makes E. coli cells extremely sensitive to manganese, characterized by arrested cell growth and filamentation. Here we demonstrate that upon complementation by hflX, manganese stress is relieved. In phenotypic studies done in a manganese-rich environment, ΔhflX cells were highly sensitive to antibiotics that bind the penicillin binding protein 3 (PBP3), suggesting that the manganese stress led to impaired peptidoglycan biosynthesis. An irregular distribution of dark bands of constriction along filaments, delocalization of the dark bands from midcell towards poles and subpoles, lack of septum formation and arrested cell division were observed in ΔhflX cells under manganese stress. However, chromosome replication and segregation of nucleoids were unaffected under these conditions, as observed from confocal microscopy imaging and FACS studies. We conclude that absence of HflX leads to manganese accumulation in E. coli cells, affecting cell septum formation, probably by modulating the activity of the cell division protein PBP3 (FtsI), a major component of the divisome apparatus. We propose that HflX acts as a gatekeeper, regulating the influx of manganese into the cell.
Related Concept Videos
Responses to Heat and Cold Stress
Responses to Salt Stress
Protection of Alcohols
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Protecting Self-Esteem

