Related Experiment Video
Updated: Feb 1, 2026

Methods for In Vivo Biomechanical Testing on Brachial Plexus in Neonatal Piglets
Published on: December 19, 2019
Biomechanical Comparison of Fifth Carpometacarpal Fusion Methods: Kirschner Wires Versus Plate and Screws
Ryu Yoshida1, Elifho Obopilwe1, Craig M Rodner1
1Department of Orthopaedic Surgery, UCONN HEALTH, Farmington, CT.
Background:
Fractures and dislocations of the base of the fifth metacarpal can lead to arthritis of the fifth carpometacarpal (CMC) joint. For patients who are symptomatic and fail conservative management, arthrodesis of the fifth CMC joint can be offered. The fusion can be performed using Kirschner wires (K-wires), but can lead to complications such as pin tract infection and pin migration. A low-profile locking plate may represent an attractive alternative. The purpose of this study was to compare the biomechanical stability of these 2 fusion techniques.
Methods:
Twelve fresh frozen cadaver hands were divided into 2 groups. The first group underwent fixation of the fifth CMC joint using 2 1.6 mm (0.062 inches) diameter K-wires in a cross-pin configuration. The second group underwent fixation using a 2.0 mm locking plate with 2 locking screws in the hamate and 3 nonlocking screws in the fifth metacarpal shaft. The specimens were then loaded in extension until failure.
Results:
The stiffness was 15.0±7.2 N/mm for the K-wire group and 14.7±6.0 N/mm (mean±SD) for the plate group (P=0.9366). The peak loads were 62.5±40.0 N and 64.6±24.8 N for K-wire and plate groups, respectively (P=0.9181). The energy to peak load was 294±281 N mm for the K-wire group and 418±190 N mm for the plate group (P=0.3904).
Conclusions:
Fifth CMC fusion using either K-wires or plate and screws showed no significant difference in stiffness, peak load, and energy to peak load. These results suggest the 2 methods provide similar biomechanical stability.
Related Concept Videos
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
The Sense of Self: Reflected Self-Appraisal and Social Comparison

