Related Experiment Video
Updated: Feb 1, 2026

Implantation of Total Artificial Heart in Congenital Heart Disease
Published on: July 18, 2014
Reducing Radiation Exposure in Cardiac Catheterizations for Congenital Heart Disease
Chandni Patel1, Matthew Grossman2, Veronika Shabanova3
1Pediatric Cardiology, Yale School of Medicine, 333 Cedar St, LLCI 302, New Haven, CT, 06510, USA. chandni320@gmail.com.
Abstract:
Ionizing radiation exposure is a necessary risk entailed during congenital cardiac catheterizations. The congenital catheterization lab at Yale New Haven Children's Hospital employed quality improvement strategies to minimize radiation exposure in this vulnerable population. In two phases, we implemented six interventions, which included adding and utilizing lower fluoroscopy and digital angiography (DA) doses, increasing staff and physician radiation awareness, focusing on tighter collimation, and changing the default fluoroscopy and DA doses to lower settings. Post-intervention data were collected prospectively for all procedures in the congenital catheterization lab and compared to pre-intervention radiation data collected retrospectively. Radiation exposure was measured in total air kerma (mGy), dose area product per body weight (DAP/kg) (µGy m2/kg), and fluoroscopy time (min). Data were collected for a total of 312 cases. In considering all procedures, the DAP/kg decreased by 67.6% and air kerma decreased by 63%. Fluoroscopy time did not change over the study period. Significant decreases in radiation exposure (DAP/kg) by procedure type were seen for atrial septal defect, patent ductus arteriosus, and transcatheter pulmonary valve procedures with a 45%, 42% and 83% decrease, respectively. Air kerma decreased significantly for ASD and PDA procedures with an 80% and 72% decrease, respectively. When compared to national benchmarks, the median DAP/kg and air kerma for these procedures are lower at our institution. The decreases continue to be sustained 2 years post-interventions. Systems-based interventions can be readily implemented in the congenital cardiac catheterization lab with dramatic and sustainable radiation dose reduction for patients.
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization IV: Nursing Management
Biological Effects of Radiation
Physiology of the Heart: The Cardiac Cycle
Diastole: The Relaxation Phase
During diastole, all four heart chambers relax. The atrioventricular (AV) valves open, and the semilunar valves close. This phase sees the lowest chamber pressures, promoting ventricular filling. Venous blood enters the heart through the...