Randomized Controlled Clinical Trial of All-Ceramic Single-Tooth Implant Reconstructions Using Modified Zirconia
Abstract:
The objective of this trial study was to assess whether submucosal veneering of internally connected zirconia abutments influences clinical, radiographic, and technical outcomes of single-tooth implant-borne reconstructions at 5 years after loading. A total of 20 patients with 20 single-tooth implants in the anterior or premolar area of the maxilla or mandible were included. The implants were randomly restored with fixed single-tooth reconstructions using either pink-veneered customized zirconia abutments (test group = 10) or nonveneered customized zirconia abutments (control group = 10). All reconstructions were adhesively cemented with all-ceramic crowns. Follow-up examinations were performed at baseline (7 to 10 days after crown insertion) and at 1, 3, and 5 years after loading, at which points the following were assessed: periodontal parameters such as probing depth (PD), bleeding on probing (BOP), and marginal bone levels, as well as technical outcomes using the modified United States Public Health Service (USPHS) criteria. Statistical comparisons were based on the Wilcoxon-Mann-Whitney test. Sixteen patients attended the 5-year follow-up. At 5 years, the implant survival rate was 100% and the prosthetic survival rate was 94.1% (one abutment fracture in the test group). Veneering of the submucosal part of zirconia abutments resulted in significantly higher mean PD values: 3.6 ± 0.4 mm (test group) and 3.0 ± 0.5 mm (control group), P = .042. Marginal bone levels at 5 years and changes up to 5 years were not significantly different between groups (P > .05). One crown exhibited an abutment fracture and two crowns a minor chipping (17.6% overall technical complication rate). Limited by a small sample size, veneering of the submucosal part of internally connected zirconia abutments led to outcomes that were less favorable biologically (PD, BOP, and KM), but similar to nonveneered abutments radiographically and technically.
Related Concept Videos
Clinical Trials
There are four phases in a clinical trial. A phase one...
Clinical Trials: Overview
Load-frequency control
Load along a Single Axis
Consider a beam of length L subjected to a varying load, which is a combination of parabolic and trapezoidal load distribution along the x-axis. In this case, it is essential to determine the resultant loads, their locations, and...
Statistical Software for Data Analysis and Clinical Trials
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...


