T-plate fixation for unstable proximal clavicula fractures
Yi Zheng1, Xin-Hua Yuan1, Yi-Hong Yin2
1Department of Orthopaedics, Ningbo, People's Republic of China.
Objective:
The aim of this study was to evaluate the clinical results of T-plate fixation and anterior sternoclavicular ligament repair in proximal clavicle fractures.
Methods:
Between August 2013 and August 2016, a total 12 patients (10 men and 2 women; mean age: 44.1 ± 9.1 years (range, 25-59 years)) with unstable proximal clavicle fractures (Throckmorton, type D) were treated with T-type plate fixation, bridging the sternoclavicular joint, and anterior sternoclavicular ligament repair. Average operative time, associated injuries, postoperative complications, postoperative fracture healing time and follow-up time were recorded. The outcomes were evaluated with radiographic assessment, visual analog scale (VAS) pain score and Rockwood SCJ scoring system. All the patients were evaluated on postoperative 3rd, 6th, and 12th months.
Results:
The average surgery time was 78.0 ± 8.47 minutes while fracture healing time was 4.51 ± 0.95 months. According to Rockwood SCJ scoring system, 9 cases (75%) were in excellent, 2 cases (16.7%) in good and 1 case (8.3%) in fair condition at 12 months follow-up. The average Rockwood SCJ score was 7.7 ± 0.75 preoperatively, 12.7 ± 0.86 by 3 months, 13.0 ± 0.73 by 6 months and 13.3 ± 0.49 by 12 months. The VAS pain score was 7.9 ± 1.15 (preoperative score), 3.4 ± 1.52 (3 months follow-up), 3.0 ± 1.32 (6 months follow-up) and 2.1 ± 1.07 (12 months follow-up). The VAS and Rockwood SCJ scores were significantly improved postoperatively (p < 0.05). There was no intraoperative complication, while one patient had redislocation of the sternoclavicular joint after implant removal.
Conclusion:
T-type plate fixation with anterior sternoclavicular ligament repair might be a reliable and effective treatment method in unstable proximal clavicle fractures (type D) with few complications and satisfactory clinical results after 12 months follow-up.
Level Of Evidence:
Level IV, therapeutic study.
More Related Videos
05:45Author Spotlight: Exploring Regeneration in Axolotls Through Insights in Cellular and Molecular Mechanisms, Bone Healing, and Implications for Human Therapies
Published on: April 12, 2024
08:04Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis
Published on: March 11, 2017
Related Concept Videos
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Carbon-dioxide Fixation
Factors Influencing Attraction I: Proximity
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Electric Field of Parallel Conducting Plates
Consider a cross-section of a thin, infinite conducting plate having a positive charge. For such a large thin plate, as the thickness of the plate tends to zero, the positive charges lie on the plate's two large faces. Without an external electric field, the...