Extraction of a trapped pacemaker lead in a pacemaker-dependent patient
Alexander Kypta1, Hermann Blessberger1, Juergen Kammler1
1Department of Internal Medicine 1 - Cardiology, Linz General Hospital, Johannes Kepler University School of Medicine, Linz, Austria.
Pacemaker pocket infections necessitate system removal. In complex cases, simultaneous removal and new system implantation, though not ideal, can be successful using specialized tools for lead extraction.
Area of Science:
- Cardiology
- Infectious Diseases
Background:
- A 47-year-old female presented with a suspected pacemaker pocket infection.
- The patient had a complex cardiac history including tricuspid valve endocarditis, multiple valve replacements, and pacemaker implantation.
Purpose of the Study:
- To describe a complex case of transvenous pacemaker lead extraction due to infection.
- To highlight the challenges and successful management of a pacemaker pocket infection in a patient with a history of multiple cardiac interventions.
Main Methods:
- Diagnosis of Staphylococcus epidermidis pocket infection confirmed by swab test.
- Surgical explantation of the infected pacemaker system and implantation of a new system on the contralateral side.
- Utilized specialized tools including a locking stylet and the Evolution device for complex lead extraction.
Main Results:
- Successful explantation of the infected pacemaker system and lead.
- Implantation of a new pacemaker system on the left side.
- Resolution of infection and symptoms after the procedure.
Conclusions:
- Pacemaker pocket infections require complete system explantation.
- While simultaneous explantation and new system implantation are generally not recommended, this approach was necessary and successful in this complex case.
- Advanced tools facilitate successful extraction of complex, chronically implanted pacemaker leads.
More Related Videos
09:20Microelectrode Array Recording of Sinoatrial Node Firing Rate to Identify Intrinsic Cardiac Pacemaking Defects in Mice
Published on: July 5, 2021
08:52Generation of Murine Cardiac Pacemaker Cell Aggregates Based on ES-Cell-Programming in Combination with Myh6-Promoter-Selection
Published on: February 17, 2015
Related Concept Videos
Social Traps
Temperature Dependence on Reaction Rate
Atoms, molecules, or ions must collide before they can react with each other. Atoms must be close together to form chemical bonds. This premise is the basis for a theory that explains many observations regarding chemical kinetics, including factors affecting reaction rates.
The collision theory is based on the postulates that (i) the reaction rate is proportional to the rate of reactant collisions, (ii) the reacting species collide in an orientation allowing contact between...
Frequency-dependent Selection
Phase-lead and Phase-lag Controllers
Drug Dependence
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...