Hepatocyte Injury Induced by Contrast-Enhanced Diagnostic Ultrasound
Douglas L Miller1, Xiaofang Lu1, Mario Fabiilli1
1Department of Radiology, University of Michigan Health System, Ann Arbor, Michigan, USA.
Objectives:
Contrast-enhanced diagnostic ultrasound (US) has a potential to induce localized biological effects. The potential for contrast-enhanced diagnostic US bioeffects in liver were researched, with guidance from a report by Yang et al (Ultrasonics 2012; 52:1065-1071).
Methods:
Contact and standoff scanning was performed for 10 minutes with a diagnostic US phased array at 1.6 MHz during bolus injection or infusion of a contrast agent at a high dose. The impact of the imaging on rat liver was investigated by measuring enzyme release, microvascular leakage, and staining of injured hepatocytes.
Results:
The results showed liver enzyme release at 30 minutes, indicating liver injury, and elevated extraction of Evans blue dye, indicating microvascular leakage. In addition, Evans blue and trypan blue vital-staining methods revealed scattered stained cells within the US scan plane. For the Evans blue method, fluorescent cell counts in frozen sections were greatest for standoff exposure with contrast infusion. The count decreased strongly with depth for bolus injection, which was probably reflective of the high attenuation noted for this agent delivery method.
Conclusions:
The results qualitatively confirmed the report by Yang et al and additionally showed hepatocyte vital staining. Research is needed to determine the threshold for the effects and the contrast agent dose response.
Related Concept Videos
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Self-Evaluation: Self-Enhancement and Self-Verification
Bioavailability Enhancement: Drug Solubility Enhancement
Bioavailability Enhancement: Drug Permeability Enhancement