Related Experiment Video
Updated: Feb 1, 2026

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Safety outcomes of new versus old generation transcatheter aortic valves
Ariel Finkelstein1, Zach Rozenbaum1, Sophia Zhitomirsky1
1Cardiology department, Tel Aviv Sourasky Medical Center, Israel, Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
Objective:
To compare procedural outcomes of transcatheter aortic valve implantation (TAVI) patients who were implanted with older versus newer generation valves.
Background:
The current evidence base for improved safety of the newer commercially available TAVI valves is limited.
Methods:
A retrospective analysis of the Israeli multicenter TAVI registry was performed. Patients were stratified by valve generation of four commercially available devices: Edwards Sapien (ESX) Edwards Sapien S3 (ES3), Medtronic CoreValve (MCV), and Medtronic Evolut R (MER).
Results:
The cohort consisted of 737 patients with new generation valves (NGVs; ES3 n = 223; MER n = 514) and 1,869 with old generation valves (OGVs; MCV n = 1,181; ESX n = 688). Device success rates were significantly higher in NGV (97.5 versus 95.4%), with less post-procedural paravalvular leak (3 versus 5.8%), and valve mal-positioning (1.2 versus 3.4%); all P-values<0.05. There were no differences in rates of permanent pacemaker implantation, stroke or acute kidney injury (AKI) of any stage between the groups, although stage ≥2 AKI was more prevalent in NGV. After adjustment to significant differences in baseline patient and procedural characteristics, device success was higher (OR 1.86, 95% confidence interval (CI) 1.09-3.18, P = 0.023) and the 1-month safety outcome was significantly lower (OR 0.72, 95% CI 0.55-0.96, P = 0.025) for NGV. Device success was driven mainly by improved rates of PVL of ES3, while the safety outcome was mainly driven by improved rates of life-threatening bleeding and valve mal-positioning of MER.
Conclusion:
As compared to OGV, use of NGV for TAVI was associated with higher rates of device success and lower rates of adverse events.
Related Concept Videos
Survey Safety
Predicting Reaction Outcomes
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...
Household Wiring And Electrical Safety
Guidelines for Writing Outcome
Patient outcomes reflect the patient's response to the goal rather than what the nurse aims to achieve. Terminology should be observable and measurable to avoid the reader's interpretation. The desired outcome should be realistic and achievable in the designated care timeframe. Expected outcomes should align with adjunctive therapies. The outcome should enhance care...

