Related Experiment Video
Updated: Feb 1, 2026

Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
On-line coupling of hydrophobic interaction column with reverse phase column -charged aerosol detector/mass
Yan He1, Paul Brown1, Michele R Bailey Piatchek1
1Analytical R&D, Pfizer BioTherapeutics R&D Pharmaceutical Sciences, 700 Chesterfield Parkway West, Chesterfield, MO 63017, United States.
Abstract:
Polysorbates are complex mixtures of over a thousand components with a wide range of hydrophobicity. This paper describes a methodology for characterization of heterogeneity and stability of polysorbates in therapeutic protein formulation. The method utilizes on-line coupling of a hydrophobic interaction chromatography (HIC) column with reverse phase liquid chromatography (RPLC) and charged aerosol detection (CAD)/mass spectrometer (MS). The addition of a low concentration of formic acid and organic solvent (e.g. 0.05% formic acid and 3% acetonitrile) in the mobile phase enables the use of the HIC column to separate small molecule excipients (including major components of polysorbates) and the large protein molecules by a mixed mechanism of size exclusion chromatography (SEC) and RPLC. The protein and the charged excipients, which elute early from the HIC column, are directed by a switching valve to waste. The polysorbates and other neutral excipients, which elute later from the HIC column, are directed to the RPLC column for further separation. The separated polysorbate components are detected by CAD, and characterized by MS. This method has been used to characterize the degradation of polysorbate 80 (PS80) in placebo and protein formulations. Our studies have revealed different degradation behavior of PS80 in placebo vs. protein formulation.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Muscles of the Vertebral Column
Superficial Layer:
The superficial layer consists primarily of the splenius muscles, which include the splenius capitis and splenius cervicis. These muscles are mainly responsible for the head and cervical spine movements, including extension, rotation, and lateral bending. The splenius capitis...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Mass Spectrometers
Principles Of Column Chromatography
Articulations of the Vertebral Column