Related Experiment Video
Updated: Feb 1, 2026

Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Reliability of effective arterial elastance using peripheral arterial pressure as surrogate for left ventricular
Manuel Ignacio Monge Garcia1, Zhongping Jian2, Jos J Settels2
1Unidad de Cuidados Intensivos, Hospital Universitario SAS de Jerez, C/ Circunvalación, s/n, 11407, Jerez de la Frontera, Spain. ignaciomonge@gmail.com.
Abstract:
To compare the effective arterial elastance (Ea) obtained from the arterial pressure with Ea calculated from left-ventricular (LV) pressure-volume analysis. Experimental study. LV pressure-volume data was obtained with a conductance catheter and arterial pressures were measured via a fluid-filled catheter placed in the proximal aorta, femoral and radial arteries. Ea was calculated as LV end-systolic pressure (ESP)/stroke volume (SV). Experimental protocol consisted sequentially changing afterload (phenylephrine/nitroprusside), preload (bleeding/fluid), and contractility (esmolol/dobutamine). 90% of systolic pressure (Eaao_SYS, Eafem_SYS, Earad_SYS), mean arterial pressure (Eaao_MAP, Eafem_MAP, Earad_MAP), and dicrotic notch pressure (Eaao_DIC, Eafem_DIC, Earad_DIC) were used as surrogates for LV ESP. SV was calculated from the LV pressure-volume data. When Ea was compared with estimations based on 90% SAP, the relationship was r2 = 0.95, 0.94 and 0.92; and the bias and limits of agreement (LOA): - 0.01 ± 0.12, - 0.09 ± 0.12, - 0.05 ± 0.15 mmHg ml-1, for Eaao_SYS, Eafem_SYS and Earad_SYS, respectively. For estimates using dicrotic notch, the relationship was r2 = 0.94, 0.95 and 0.94 for Eaao_DIC, Eafem_DIC and Earad_DIC, respectively; with a bias and LOA: 0.05 ± 0.11, 0.06 ± 0.12, 0.10 ± 0.12 mmHg ml-1, respectively. When Ea was compared with estimates using MAP, the relationship was r2 = 0.95, 0.96 and 0.95 for Eaao_MAP, Eafem_MAP and Earad_MAP, respectively; with a bias and LOA: 0.05 ± 0.11, 0.06 ± 0.11, 0.06 ± 0.11 mmHg ml-1, respectively. LV ESP can be estimated from the arterial pressure. Provided that the SV measurement is reliable, the ratio MAP/SV provides a robust Ea surrogate over a wide range of hemodynamic conditions and is interchangeably in any peripheral artery, so it should be recommended as an arterial estimate of Ea in further research.
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Peripheral Artery Disease I: Introduction
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Vapor Pressure
Peripheral Artery Disease IV: Nursing Management