Related Experiment Video
Updated: Feb 1, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Using Aorta-Lesion-Attenuation Difference on Preoperative Contrast-enhanced Computed Tomography Scan to Differentiate
Joseph R Grajo1, Russell S Terry2, Justin Ruoss1
1Departments of Radiology, University of Florida College of Medicine, Gainesville, FL.
Objective:
To evaluate the ability of Aorta-Lesion-Attenuation Difference (ALAD) to differentiate malignant renal tumors from renal oncocytomas.
Methods:
A retrospective review of preoperative computed tomography (CT) scans and surgical pathology was performed on patients undergoing partial nephrectomy for small, solid renal masses. ALAD was calculated by measuring the difference in Hounsfield units (HU) between the aorta and the lesion of interest on the same image slice on preoperative CT scan. The discriminative ability of ALAD to differentiate malignant pathology from oncocytoma was evaluated by sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under curve (AUC) using receiver operating characteristic analysis.
Results:
A total of 227 preoperative CT scans and corresponding pathology reports were reviewed. ALAD values were calculated during the excretory and nephrographic phases. Nephrographic ALAD was able to differentiate malignant pathology from oncocytoma using a HU threshold of 24 with a sensitivity of 84%, specificity of 86%, PPV of 98%, and NPV of 33%. The AUC for malignant pathology vs oncocytoma was 0.86 (95% confidence intervals 0.77-0.96). Nephrographic ALAD was able to differentiate chromophobe renal cell carcinoma (RCC) from oncocytoma using a HU threshold of 24 with a sensitivity of 100%, specificity of 86%, PPV of 75%, and NPV of 100%. The AUC for chromophobe RCC vs oncocytoma was 0.98 (95% confidence intervals 0.91-1.00).
Conclusion:
ALAD discriminates well between chromophobe RCC and oncocytoma, which may aid in the management of patients with indeterminate diagnoses of oncocytic neoplasm on diagnostic needle biopsy. Further validation of ALAD will be necessary prior to routine use in clinical practice.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Studies III: Computed Tomography
Transcription Attenuation in Prokaryotes
There are several different mechanisms used to attenuate transcription. In ribosome mediated...
Leaky Scanning
The Aorta
The average diameter of the aorta is approximately 2-3 cm, but the size can vary depending on the section of the aorta and the individual's age, sex, and body size. The aorta is...