Morphologic characteristics of severe basilar artery atherosclerotic stenosis on 3D high-resolution MRI
Runcai Guo1, Xuebin Zhang1, Xianjin Zhu2
1Department of Radiology, China-Japan Friendship Hospital, 2 Yinghuayuan Dongjie, Beijing, China.
Background:
Two-dimensional high-resolution MRI (2D HRMRI) faces many technical challenges for fully assessing morphologic characteristics of inherent tortuous basilar arteries. Our aim was to investigate remodeling mechanisms and plaque distribution in symptomatic patients with basilar artery stenosis on three-dimensional (3D) HRMRI.
Methods:
Forty-six consecutive patients with symptomatic basilar artery atherosclerotic stenosis on MRA (70-99%) were enrolled. The remodeling index (RI) was the ratio of vessel area at the maximal-lumen-narrowing (MLN) site to reference vessel area. RI ≥ 1.05 was defined as positive remodeling (PR), RI ≤ 0.95 as negative remodeling (NR), and 0.95 < RI < 1.05 as intermediate remodeling (IR). The remodeling patterns were divided into two groups (PR and non-PR [NR and IR]). The cross-sectional and longitudinal distribution of BA plaques were evaluated.
Results:
Two patients were excluded because of poor-quality images. Images of 44 patients were available for measurements. PR was found in 23 (52.3%) patients, and non-PR in 21 (47.7%) patients. At the MLN sites, vessel area, wall area, plaque size and percentage of plaque burden of PR group were significantly greater than non-PR group (p < .001). Most plaques (90.9%) of the 44 patients were located at the dorsal, left and right walls. For the longitudinal distribution of plaque, 8 (18.2%) and 36 (81.8%) plaques were located in BA proximal and distal to AICA, respectively. Most plaques (68.2%) were eccentrically distributed.
Conclusions:
3D HRMRI with postprocessing multiple planar reconstruction is able to evaluate the remodeling pattern and plaque distribution of basilar artery atherosclerotic stenosis, which might be used to guide intracranial intervention.
More Related Videos
07:19Recording of Inward Rectifying K+ Currents in Freshly Isolated Basilar Artery Smooth Muscle Cells by Patch Clamp Technique
Published on: February 7, 2025
06:39Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
Related Concept Videos
Characteristics of Life
Mitral Stenosis I: Introduction
Characteristics of Fluids
Characteristics of Fluids
Fluids, which include both liquids and gases, are substances that deform continuously under shearing stress. For example, water and oil are liquids with molecules that can...
Characteristics of BJT
For input characteristics, the base-emitter voltage is varied, maintaining a constant collector-emitter voltage. This setup reveals a Shockley-type dependence of the collector current on...
Characteristics of JFET
The core of a JFET's operation is controlling drain current by modulating the gate-source voltage. When the drain and gate voltage are set to zero, the JFET exhibits no net current flow, representing a state of equilibrium. The drain current increases linearly as the...