Accuracy of Response Assessment Positron Emission Tomography-Computed Tomography Following Definitive Radiotherapy
M Arunsingh1, S Vaidyanathan2, K E Dyker1
1Department of Clinical Oncology, Leeds Cancer Centre, Leeds, UK.
Aim:
There are few data to inform on the use of response assessment 2-[fluorine-18]-fluoro-2-deoxy-d-glucose (FDG) positron emission tomography-computed tomography (PET-CT) following radical radiotherapy without chemotherapy for head and neck squamous cell carcinoma (HNSCC). This retrospective study evaluated the accuracy of PET-CT in HNSCC following radical radiotherapy.
Materials And Methods:
In total, 138 patients with HNSCC treated with radical radiotherapy without chemotherapy who underwent a baseline and response assessment FDG PET-CT were identified. FDG PET-CT outcomes were analysed with reference to clinicopathological outcomes.
Results:
The median follow-up was 26 months. FDG-avid disease at baseline was present for the primary site and lymph nodes in 118 and 86 patients, respectively. With regard to the primary tumour, the negative predictive value (NPV) of a complete metabolic response (CMR) was 95%; the positive predictive value (PPV) of equivocal uptake and a positive scan were 6% and 82%, respectively. The likelihood ratios for a CMR, equivocal and positive scans of the primary site were 0.19, 0.22, 14.8, respectively. With regard to lymph node disease, the NPV of a CMR was 91%, the PPV of equivocal uptake and a positive scan were 33% and 88%, respectively. Likelihood ratios for lymph node disease for CMR, equivocal and positive scans were 0.19, 0.97 and 15.1, respectively.
Conclusion:
Compared with the accuracy reported in the literature following chemoradiotherapy, response assessment FDG PET-CT following radical radiotherapy without chemotherapy had a similarly high NPV, whereas the PPV following a positive scan was higher.
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
05:32Multimodal Bioluminescent and Positronic-emission Tomography/Computational Tomography Imaging of Multiple Myeloma Bone Marrow Xenografts in NOG Mice
Published on: January 7, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Arteries of the Head and Neck
The internal carotid arteries supply blood to the anterior portion of the cerebrum. They enter the...
Veins of Head and Neck
On the other hand, the vertebral veins, unlike their arterial counterparts, are not primarily responsible for brain drainage. Instead, they drain the cervical vertebrae, spinal cord, and some small...