Push dose pressors: Experience in critically ill patients outside of the operating room
Andrew Rotando1, Lindsey Picard1, Samantha Delibert2
1Department of Emergency Medicine, University of Rochester Medical Center, 601 Elmwood Ave., Box 655, Rochester, NY 14642, United States of America.
Purpose:
Evaluate push dose vasopressor (PDP) practice patterns, efficacy, and safety in critically ill patients.
Methods:
Critically ill patients receiving phenylephrine or ephedrine PDP from November 2015-March 2017 were included. Patient demographics, medication administration details, vital signs pre- and post-administration, adverse effects, and medications errors were collected. Descriptive data are presented and comparisons were made with paired samples t-test, Wilcoxon Rank Sum and Chi-squared analysis or Fisher's Exact Test as appropriate.
Results:
A total of 146 patients (155 PDP events) were included; mean age 64.5 ± 13.3 years and 66.4% males, respiratory failure (39.8%) or sepsis (24.9%) admission diagnosis. The surgical intensive care unit (ICU) (44.5%) and medical ICU (33.6%) used PDPs most often, and during the peri-intubation period (57.3%) or for other transient hypotension (38.2%). Following PDP, mean systolic blood pressure (BP), diastolic BP, and heart rate (HR) increased 32.5% (80 to 106 mmHg), 27.2% (48 to 61 mmHg), and 6.4% (93 to 99 bpm), respectively. There were 17 (11.6%) adverse events; most often related to excessive increases in BP or HR and one incidence of dysrhythmia. Thirteen patients (11.2%) had a dose related medication error (phenylephrine dose >200 μg or ephedrine dose >25 mg), nine (6.2%) received PDP with normal/elevated hemodynamics (systolic BP > 100 mmHg or HR > 160 bpm) and 15% while on a continuous infusion vasopressor.
Conclusion:
PDPs were used in a variety of patient diagnoses and for select indications. Overall, they were efficacious but associated with adverse drug events and medication errors.
More Related Videos
Related Concept Videos
Drug Dosing: Geriatric Patients
Drug Dosing: Obese Patients
Critical Region, Critical Values and Significance Level
In hypothesis testing, a sample statistic is converted to a test statistic using z, t, or chi-square distribution. A critical region is an area under the curve in probability distributions demarcated by the critical value. When the test statistic falls in this region, it suggests that the null hypothesis must be rejected. As this region contains all those values of the...
Critical Values
Drive-Reduction Theory: Push Theory of Motivation
Critical Thinking I