Computed tomographic colonography with a reduced dose of laxative using a novel barium sulfate contrast agent in
Katsuhiko Mitsuzaki1, Gen Iinuma2, Tsuyoshi Morimoto3
1Center for Preventive Medicine, Saiseikai Kumamoto Hospital, 5-3-1 Chikami, Minami-ku, Kumamoto, Kumamoto, Japan. katsuhiko-mitsuzaki@saiseikaikumamoto.jp.
Purpose:
To test the tagging efficacy, patient acceptability, and accuracy of computed tomographic colonography (CTC) with a reduced dose of laxative using a novel barium sulfate (BaSO4) contrast agent.
Materials And Methods:
CTC followed by optical colonoscopy (OC) was performed on 73 patients with positive results in fecal occult blood tests. They were administrated a BaSO4 suspension and a magnesium citrate solution for bowel preparation. Patients completed a questionnaire about the acceptability of bowel preparation. Tagging efficacy was estimated using a novel categorization system, which classified all segments into 8 categories. The accuracy of detecting protruded lesions ≥ 6 mm was calculated from the comparison of CTC and OC results, using the latter as a reference standard.
Results:
Tagging efficacy was good in 77.3% of colonic segments where residue was observed. The acceptability of bowel preparation for CTC was significantly higher than that for OC. The sensitivity, specificity, and positive and negative predictive values were 0.778, 0.945, 0.824, and 0.929, respectively. All lesions ≥ 7 mm were successfully detected by CTC.
Conclusion:
CTC with a reduced dose of laxative using a novel BaSO4 contrast agent has a favorable tagging efficacy, patient acceptability, and accuracy.
Related Concept Videos
Redox Titration: Other Oxidizing and Reducing Agents
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Drugs Affecting GI Tract Motility: Other Laxatives
Osmotic or saline laxatives, like magnesium hydroxide or milk of...
Sulfate Attack on Concrete
Sulfates from sources like soil, groundwater, or industrial effluents...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...