Biomechanical investigation of tibial tubercle osteotomy fixed with various screw configurations
Chih-Wei Chang1, Yen-Nien Chen2, Chun-Ting Li3
1Department of BioMedical Engineering, National Cheng Kung University, Tainan City, Taiwan; Department of Orthopedics, College of Medicine, National Cheng Kung University, Tainan City, Taiwan; Department of Orthopedics & Joint Reconstruction Center, National Cheng Kung University Hospital, Collage of Medicine, National Cheng Kung University, Tainan City, Taiwan.
Introduction:
To date, the effects of various screw configurations on the stability of tibial tubercle osteotomy (TTO) are not completely understood. Hence, the first aim of this study is to evaluate the stability of TTO under various screw configurations. The second aim is to evaluate the internal stresses in the bone and the contact forces on the bone fragment that are developed by the tibia and screws in response to the applied load after the equilibrant is revealed.
Methods:
To calculate the biomechanical responses of the bone and screw under loading, finite element (FE) method was used in this study. Six types of screw configurations were studied in the simulation: two parallel horizontal screws placed at a 20 mm interval, two parallel horizontal screws placed at a 30 mm interval, two parallel upward screws, two parallel downward screws, two trapezoid screws, and two divergent screws. The displacement of the bone fragment, contact forces on the fragment, and the internal stress in the bone were used as indices for comparison.
Results:
Among all configurations, the configuration of two parallel downward screws yielded the highest stability with the lowest fragment displacement and gap opening. Although the maximum displacement of the TTO with the configuration of two parallel horizontal screws was slightly higher than that of the downward configuration, the difference was only 0.2 mm. The configuration of two upward screws resulted in the highest fragment displacement and gap deformation between the fragment and tibia. The stress of the osteotomized bone fragment was highest with the configuration of two upward screws.
Conclusion:
Based on the present model, the current configuration of two parallel horizontal screws is recommended for TTO. If this is inappropriate in a specific clinical scenario, then the downward screw configuration may be used as an alternative. By contrast, the configuration of two parallel upward screws is least suggested for the fixation of TTO.
Related Concept Videos
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Electron Configurations
The relative energies of the subshells determine the order in which atomic orbitals are filled (1s, 2s, 2p, 3s, 3p,...
Electron Configuration of Multielectron Atoms
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Configurations of BJT
The common base configuration is noted for its high voltage gain, positioning it as an ideal choice for single-stage amplifier circuits, such as microphone pre-amplifiers. A notable...