Objectives:
To investigate the effect of TAVR technique on in-hospital and 30-day outcomes in patients with aortic stenosis (AS) and reduced ejection fraction (EF).
Background:
Patients with AS and concomitant low EF may be at risk for adverse hemodynamic effects from general anesthesia utilized in transcatheter aortic valve replacement (TAVR) via the conventional strategy (CS). These patients may be better suited for the minimally invasive strategy (MIS), which employs conscious sedation. However, data are lacking that compare MIS to CS in patients with AS and concomitant low EF.
Methods:
In this retrospective study, we identified all patients with low EF (<50%) undergoing transfemoral MIS-TAVR vs CS-TAVR between March 2011 and May 2018. Our primary endpoint was defined as the composite of in-hospital mortality and major periprocedural bleeding or vascular complications.
Results:
Two hundred and seventy patients had EF <50%, while 154 patients had EF ≤35%. Overall, a total of 236 patients were in the MIS group and 34 were in the CS group. Baseline characteristics between the two groups were similar except for Society of Thoracic Surgeons (STS) score (MIS 8.4 ± 5.1 vs CS 11.7 ± 6.8; P<.01). There were no differences between the two groups in incidence of the primary endpoint (MIS 5.5% vs CS 8.8%; odds ratio for MIS, 0.60; 95% confidence interval, 0.16-2.23; P=.45).
Conclusions:
In patients with severe AS and reduced EF, MIS was not associated with adverse in-hospital or 30-day clinical outcomes compared with CS. In these patients, MIS may be a suitable alternative to CS without compromising clinical outcomes.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Persuasion Strategies
Coping Strategies: Problem Focused
For example, consider a student who struggles to understand their...
Heart Failure II: Pathophysiology
Pathophysiology of Heart Failure
Heart Failure I: Introduction