Related Experiment Video
Updated: Feb 1, 2026

C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
Published on: September 16, 2022
Cervical Spondyloptosis Successfully Treated with Only Posterior Short Segment Fusion Using Cervical Pedicle Screw
Min Woo Kim1, Su Bum Lee1, Jin Hoon Park1
1Department of Neurological Surgery, Asan Medical Center, University of Ulsan College of Medicine.
Abstract:
This paper describes two patients with cervical spondyloptosis with severe spinal cord injury treated with cervical pedicle screw (CPS) through a single-stage operation, posterior approach. A 60-year-old male patient with quadriparesis due to trauma 1 day before visited the emergency room. Cervical spine computed tomography (CT) and magnetic resonance imaging showed complete dislocation of the C7 and T1 vertebrae with severe spinal cord compression, disc injury, and disc herniation at the C7-T1 level. Cervical pedicle screw with freehand technique was done on C6 and T1 vertebrae, and bilateral distraction for a reduction was performed with a screw distractor. After reduction of the C7 vertebra on the surgical field, CPS placement on C7 body was done. After surgery, follow-up X-rays showed near complete reduction. The patient completed a rehabilitation program, and his condition improved. From the third month postoperatively, the patient could ambulate without assistance and perform nearly normal daily activities. A postoperative CT scan 1 year later showed accurate screw position and complete fusion bridges on the C6-C7-T1 vertebrae. The other patient, a 39-year-old male, also showed C7-T1 spondyloptosis with quadriparesis (grade IV). C6-T1-T2 fusion surgery was performed only through a posterior approach. The patient showed nearly normal neurology and reduction. Considering early surgery time followed by open reduction and biomechanical superiority of CPS, single posterior approach and short segment fusion appear to be a great surgical method.
Related Concept Videos
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Carbon-dioxide Fixation