Related Experiment Video
Updated: Feb 1, 2026

Muscle Imbalances: Testing and Training Functional Eccentric Hamstring Strength in Athletic Populations
Published on: May 1, 2018
Validity and Reliability of a Non-invasive Test to Assess Quadriceps and Hamstrings Strength in Athletes
Davide Mondin1, Julian A Owen1, Massimo Negro2
1School of Sport, Health and Exercise Sciences, Bangor University, Bangor, United Kingdom.
Abstract:
Modifiable risk factors for hamstring injury include lack of strength, fatigue and muscle strength asymmetry. Assessing lower body strength in the field is problematic as "gold standard assessment" are expensive, non-portable and assessment is time-consuming. Therefore, the objective of this study was to examine the validity and reliability of an adapted aneroid sphygmomanometer test of hamstring and quadricep strength. In 14 active males (age 23.1 ± 2.5 years; height 180.9 ± 8.2 cm; weight 88.4 ± 8.5 kg). concurrent validity was assessed by comparing the adapted sphygmomanometer assessment at 30 and 90° of knee flexion to isokinetic dynamometry using Pearson product-moment correlation. The reliability of the adapted sphygmomanometer was assessed in 10 professional rugby players (age 21.5 ± 2.6 years; height 177.2 ± 5.8 cm; weight 92.7 ± 5.8 kg ) across two visits. Sphygmomanometer strength assessments of hamstring and quadriceps were associated with isokinetic measures (Quadricep: right, r = 0.386, 95% CI = 0.136-0.866, p < 0.05; left, r = 0.431, 95% CI = 0.193-0.880, p < 0.05), hamstring strength at 90° of knee flexion (Hamstring: right, r = 0.545, 95% CI = 0.342-0.912, p < 0.01; left, r = 0.643, 95% CI = 0.473-0.935, p < 0.001) and hamstring strength at 30° of knee flexion (right, r = 0.329, 95% CI = 0.062-0.846, p < 0.05; left, r = 0.387, 95% CI = 0.138-0.867, p < 0.05). However, the adapted test was not able to identify bilateral or hamstring to quadricep asymmetry. Test-retest reliability was high for most assessments (ICC range: 0.64-0.92), and SEM measures ranged between 5 and 12%, with the smallest change representing a change in strength ranging between 3 and 4%. In conclusion, an adapted sphygmomanometer test for hamstring and quadricep strength assessment was valid and reliable in assessing hamstring and quadricep strength but not bilateral or hamstring and quadricep asymmetry.
Related Concept Videos
Reliability and Validity
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete
The Equilibrium Binding Constant and Binding Strength
Distribution Reliability and Automation

