Related Experiment Video
Updated: Jan 31, 2026

Creation of Colonic Anastomosis in Mice
Published on: January 17, 2019
Mechanical Dilation Using Nylon Monofilament Aids Multisite Lymphaticovenous Anastomosis Through Improving the
Shuhei Yoshida1, Isao Koshima1, Ayano Sasaki2
1From the International Center for Lymphedema and.
Abstract:
Lymphaticovenous anastomosis (LVA) is now a common treatment for lymphedema. It is important to create as many bypasses as possible to maximize the efficacy of LVA. We have developed a method whereby nylon monofilaments are placed inside the vessel lumen to act as dilators. We refer to this technique as mechanical dilation (MD) to distinguish it from intravascular stenting. In this study, we investigated the efficacy of the conventional supermicrosurgery technique performed with and without MD as a treatment for lower limb lymphedema. The LVA was performed using conventional supermicrosurgery alone in 10 patients (group without MD) and in combination with MD in another 10 patients (group with MD). The mean number of successful LVAs performed per hour was significantly higher in the group with MD than in the group without MD (1.42 ± 0.16 vs 1.14 ± 0.15; P < 0.05). The mean amount of improvement in the lower extremity lymphedema index was significantly greater in the group with MD than in the group without MD (7.34 ± 1.57 vs 4.41 ± 1.53; P = 0.003 < 0.05). A statistically significant correlation was found between the number of successful LVAs and amount of improvement in lymphedema (r = 0.449, P = 0.047 < 0.05). Our findings suggest that use of MD does not shorten the operating time or increase the number of LVAs that can be performed but may make it possible to increase the number of successful LVAs that can be performed between vessels with a diameter of less than 0.3 mm. Use of MD could increase the improvement rate of lymphedema to a greater extent than that achieved by conventional microsurgery alone.
Related Concept Videos
Cardiomyopathy II: Dilated Cardiomyopathy
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Quality Assurance
Quality of Water
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Testing Water Quality

