Related Experiment Video
Updated: Jan 31, 2026

Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods
Published on: September 6, 2024
Combination of free-breathing radial 3D fat-suppressed T1-weighted gradient-echo sequence with diffusion weighted
Shan Dang1, Xiang Gao2, Guangming Ma1
1Department of Radiology, The affiliated hospital of Shaanxi university of Chinese medicine, Xian Yang, China.
Objectives:
High resolution CT is the most commonly used radiological method for differentiating benign from malignant peripheral solid pulmonary masses, however, some of them are not easily diagnosed by morphology alone. Furthermore, due to the radiation dose, it is unsuitable for patients with disorders requiring repeated examinations over prolonged periods. The aims of this study were to evaluate whether a combination of diffusion-weighted images (DWI) and free-breathing radial 3D fat-suppressed T1-weighted gradient echo (radial volumetric interpolated breath-hold examination, radial VIBE) sequence can enable discrimination between benign from malignant peripheral solid pulmonary masses.
Materials And Methods:
Both chest CT scan and MR imaging with radial VIBE and DWI were obtained from 47 patients; 30 males and 17 females (mean age 64 years old; age range 48-83 years old). Benign and malignant peripheral solid pulmonary masses were conclusively identified by pathology results. Two radiologists independently reviewed all the images and record radiological features including morphological signs on radial VIBE, CT images, and ADC value. Receiver operating characteristic (ROC) was used to analyze the capability of radial VIBE as well as DWI to distinguish malignant from benign peripheral solid pulmonary masses.
Results:
In 77% of patients, malignant peripheral solid pulmonary masses were found. Morphological signs of mediastinal lymph node enlargement and lobulation were more easily found in malignant masses in both radial VIBE (mediastinal lymph node enlargement: p = 0.033, lobulation: p = 0.039) and CT (mediastinal lymph node enlargement: p = 0.004, lobulation: p = 0.012). The ADC value were also significant difference between benign and malignant groups (p = 0.001). Combined ADC value with radial VIBE was a most specific test than routine-dose CT (86.1% vs 75%, p < 0.001), but less sensitive than routine-dose CT (81.8% vs 90.9%; p < 0.001) for malignant peripheral solid pulmonary masses detection. Diagnostic accuracy was 89% for combining ADC value with radial VIBE, and 85% for routine-dose CT.
Conclusions:
Combination of morphological signs and ADC value seems to improve differentiating malignant from benign peripheral solid pulmonary masses. Especially in patients unable to endure radiation exposure, suspend respiration, radial VIBE provides similar morphological signs displaying to those on routine-dose CT.
Related Concept Videos
Mass and Weight
Weighted Mean
For example, consider the number of goals scored in the matches of a tournament. While computing the average number of goals scored in the tournament, it may be more important to...
Atomic Weight
Apparent Weight
Consider a person standing on a bathroom scale inside an elevator. If the scale is accurate at rest, its reading equals the...
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
Polymers: Defining Molecular Weight
The number average molecular weight (Mn) is the summation of the number...

