Related Experiment Video
Updated: Jan 31, 2026

Bacterial Detection & Identification Using Electrochemical Sensors
Published on: April 23, 2013
Sandwich-type electrochemical immunosensor for sensitive detection of CEA based on the enhanced effects of Ag NPs@CS
Chunyan Zhang1, Shuan Zhang1, Yilei Jia1
1School of Chemical Engineering, Shandong University of Technology, Zibo 255049, PR China.
Abstract:
An ultrasensitive sandwich-type electrochemical immunosensor was designed by using gold nanoparticles (Au NPs) as the substrate material and microporous carbon spheres (CS) loading silver nanoparticles (Ag NPs) spaced Hemin/reduced graphene oxide (Hemin/rGO) porous composite materials (Ag NPs@CS-Hemin/rGO) as the detection antibodies (Ab2) label for detecting carcinoembryonic antigen (CEA). The Au NPs with good electrical conductivity and biocompatibility could accelerate the electron transfer on the electrode interface and enhance the load capacity of capture antibodies (Ab1). Hemin is peroxidase-like substance which has excellent catalytic ability for H2O2 reduction but easy to molecular aggregation and oxidative self-destruction. Reduced graphene oxide (rGO) is a good supporting material for Hemin to mitigate this disadvantage. CS loading Ag NPs (Ag NPs@CS) as the spacer inserts into Hemin/rGO sheet can overcome the irreversible stacking of rGO, and form complex porous structure which exposes more active sites of Hemin. Moreover, Ag NPs loaded on CS also has catalytic ability for H2O2 reduction. Thus the Ag NPs@CS-Hemin/rGO used as the Ab2 label has a large working surface area and high utilization rate, which heightens the catalytic ability for H2O2 reduction to amplify the current signal effectually. The current signal and the logarithm of CEA concentration presented a wide linear response range of 20 fg/mL to 200 ng/mL, and the detection limit of CEA was 6.7 fg/mL. Furthermore, the designed immunosensor exhibited a good reproducibility, selectivity and stability, which confirms a broad development prospect when applying it in early clinical detection.
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Biological Effects of Radiation
Framing Effects
Space Trusses