The effect of transverse prosthetic alignment changes on socket reaction moments during gait in individuals with
Hiroshi Hashimoto1, Toshiki Kobayashi2, Fan Gao3
1Graduate School of Comprehensive Rehabilitation, Osaka Prefecture University, Habikino City, Osaka, Japan; Pacific Supply co. Ltd., Daito City, Osaka, Japan.
Background:
Alignment affects gait of individuals with transtibial prostheses. Sagittal and coronal alignment changes of the transtibial prostheses were demonstrated to affect socket reaction moments. However, the effects of transverse alignment changes on the socket reaction moments are not known.
Research Question:
The aim of this study was to investigate the effects of transverse alignment changes on the socket reaction moments and temporal-spatial parameters of gait in transtibial prostheses.
Methods:
The effects of transverse prosthetic alignment changes (i.e. 10° and 5° of internal and external rotations: toe-in and toe-out of the foot relative to the socket from a baseline alignment) on the sagittal and coronal socket reaction moments and temporal-spatial parameters (gait speed, cadence and step width) while walking in 9 individuals with transtibial amputation were investigated using an instrumented prosthetic pyramid adaptor and a three-dimentional (3D) motion capture system.
Results:
The transverse alignment changes demonstrated significant effects on the socket reaction moments in the coronal plane at 5% (P = 0.04), 20% (P = 0.04) and 75% (P = 0.0001) of stance phase. No significant effects were found in the socket reaction moments in the sagittal plane and the temporal-spatial parameters. The internal and external rotations of the prosthetic feet may have opposite effect in early and mid- to late-stance potentially due to changes in the spatial position of the heel (rearfoot) and toe (forefoot) of the prosthetic foot relative to the socket.
Significance:
Transverse alignment of the transtibial prostheses should be tuned not only considering the symmetry in toe-out angles of the feet, but also considering the potential effects of transverse alignment changes that may affect the coronal socket reaction moments.
More Related Videos
08:08Oscillation and Reaction Board Techniques for Estimating Inertial Properties of a Below-knee Prosthesis
Published on: May 8, 2014
11:16Engineering Platform and Experimental Protocol for Design and Evaluation of a Neurally-controlled Powered Transfemoral Prosthesis
Published on: July 22, 2014
Related Concept Videos
Speed of a Transverse Wave
One of the key properties of any wave is the wave speed. Light...
Deformations in a Transverse Cross Section
As the material stretches, it expands or contracts in orthogonal directions to the load. This phenomenon varies...
Impact of Individuals on Individuals
Moment of Inertia
If a rigid body is rotating about an axis but is not in translational motion, its translational kinetic energy is zero. However, since each particle undergoes rotational motion, it possesses non-zero velocity and kinetic energy. Thus, the kinetic energy of the rigid body, which is the sum of the...
Principal Moments of Area
The principal moment of inertia axes are the...
Moment-Area Theorems
The theorem is divided into two parts. The first part connects the angle between tangents at any two points on the beam's elastic curve to the area under a curve derived by...