Related Experiment Video
Updated: Jan 31, 2026

Detection of Targetable Alterations in Non-small Cell Lung Cancer using Next-generation Sequencing
Published on: October 10, 2025
CT Slice Thickness and Convolution Kernel Affect Performance of a Radiomic Model for Predicting EGFR Status in
Yajun Li1, Lin Lu2, Manjun Xiao3
1Department of Radiology, the Second Xiangya Hospital, Central South University, Changsha, Hunan, 410011, China. liyajun9966@csu.edu.cn.
Abstract:
We evaluated whether the optimal selection of CT reconstruction settings enables the construction of a radiomics model to predict epidermal growth factor receptor (EGFR) mutation status in primary lung adenocarcinoma (LAC) using standard of care CT images. Fifty-one patients (EGFR:wildtype = 23:28) with LACs of clinical stage I/II/IIIA were included in the analysis. The LACs were segmented in four conditions, two slice thicknesses (Thin: 1 mm; Thick: 5 mm) and two convolution kernels (Sharp: B70f/B70s; Smooth: B30f/B31f/B31s), which constituted four groups: (1) Thin-Sharp, (2) Thin-Smooth, (3) Thick-Sharp, and (4) Thick-Smooth. Machine learning algorithms selected and combined 1,695 quantitative image features to build prediction models. The performance of prediction models was assessed by calculating the area under the curve (AUC). The best prediction model yielded AUC (95%CI) = 0.83 (0.68, 0.92) using the Thin-Smooth reconstruction setting. The AUC of models using thick slices was significantly lower than that of thin slices (P < 10-3), whereas the impact of reconstruction kernel was not significant. Our study showed that the optimal prediction of EGFR mutational status in early stage LACs was achieved by using thin CT-scan slices, independently of convolution kernels. Results from the prediction model suggest that tumor heterogeneity is associated with EGFR mutation.
Related Concept Videos
Convolution Properties II
The width property indicates that if the durations of input signals are T1 and T2, then the width of the output response equals the sum of both durations, irrespective of the shapes of the two functions. For instance, convolving two rectangular pulses with durations of 2 seconds and 1 second results in a function with a width of 3 seconds.
The area property asserts that the area under the...
Mouse Models of Cancer Study
The development of transgenic, knockout, and knock-in mice has led to an exponential increase in their use as model organisms in research,...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Role of Affect in Interpersonal Attraction
Convolution Properties I
The commutative property reveals that the input and the impulse response of an LTI (Linear Time-Invariant) system can be interchanged without affecting the output: