Risk of extrapelvine vascular injuries in osteosynthesis with gliding hip screws
Thomas Neubauer1, St Grechenig2, H Clement3
1Department of Trauma Surgery, Federal Hospital Horn, Spitalgasse 10, 3850, Horn, Austria. thneubauer@aon.at.
Background:
Dynamic hip screw (DHS) osteosynthesis represents one of the most frequently performed fixation methods in orthopedic practice. The purpose of this study was to determine the potential risk of vascular damage by DHS side-plate screws (PS) and plunging instruments for individual femoral vessels and screw positions.
Methods:
In ten hemipelvic/leg specimens mounted with a large femur distractor, a DHS system with a four-hole side-plate was inserted. PS were inserted in 3 consecutive courses with different inclinations in the frontal plane of 0° (group 1), - 30° posterior (group 2) and + 30° anterior (group 3) in relation to the side-plate's surface, resulting in 120 PS positions. After screw tightening, the soft tissues on the medial side of the femur were dissected and investigated for vascular compromise; in each course, the effect of overshot instruments within a range of 50 mm beyond the side-plate's surface was also tested.
Results:
Totally, 37/120 screw positions (31%) revealed potential vascular compromise which comprised of 15/120 (13%) direct hits by screw tips and 22/120 (18%) potential impacts by plunging instruments. The deep femoral artery system (DFA) was significantly (p = 0.007) most often affected but no significant differences for individual vascular structures were seen. Direct vascular impacts occurred significantly more often (p = 0.0047) in screws with 0° inclination compared to + 30° inclination (p = 0.017). Significant differences among individual screw positions were only found in group - 30° with direct vessel contacts (p = 0.038).
Conclusions:
The DFA system is significantly more at risk while significant preference of a certain vessel is missing. Our data indicate that more than 30% of 120 screw positions in DHS osteosynthesis revealed a potential danger of vascular compromise, when surgical principles are denied in hip fracture fixation.
Clinical Relevance:
Though vascular complications are infrequently encountered in DHS osteosynthesis they have to be considered as a potential complication when surgical principles are not followed in this anatomic area.
More Related Videos
Related Concept Videos
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Relative Risk
Seedless Vascular Plants
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...