Related Experiment Video
Updated: Jan 31, 2026

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Left Atrial Phasic Function by Cardiac Magnetic Resonance Feature Tracking Is a Strong Predictor of Incident
Julio A Chirinos1,2,3, Mayank Sardana4, Bilal Ansari2
1Department of Radiology, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia (J.A.C., G.O., R.M., S.G., S.R.A.).
Background:
The prognostic importance of left atrial (LA) dysfunction is increasingly recognized. Magnetic resonance imaging can provide excellent visualization of the LA wall. We aimed to study the association of LA dysfunction measured using feature-tracking magnetic resonance imaging with incident adverse cardiovascular events among subjects with or without heart failure (HF) at baseline.
Methods And Results:
We prospectively studied 640 adults without HF (n=419), HF with preserved ejection fraction (n=101), or HF with reduced ejection fraction (n=120). We measured phasic LA function by volumetric and feature-tracking methods to derive longitudinal strain. The composite outcome of incident HF hospitalization or death was adjudicated during a median follow-up of 37.1 months. Measures of LA phasic function were more prominently impaired in subjects with HF with reduced ejection fraction than among subjects with HF with preserved ejection fraction. In unadjusted Cox proportional hazards models, all measures of phasic LA function and volumes (maximum, minimum, and diastatic) were associated with the composite outcome. However, in analyses that adjusted for clinical risk factors, HF status, maximum LA volume, left ventricular mass, and left ventricular ejection fraction, measures of conduit and reservoir LA function, but not booster-pump function, were associated with the composite outcome. The strongest associations were observed for conduit longitudinal strain (standardized hazard ratio, 0.66; 95% CI, 0.49-0.88; P=0.004), conduit strain rate (standardized hazard ratio, 1.59; 95% CI, 1.16-2.16; P=0.0035), and reservoir strain (standardized hazard ratio, 0.68; 95% CI, 0.52-0.89; P=0.0055).
Conclusions:
Phasic LA function measured using magnetic resonance imaging feature tracking is independently predictive of the risk of incident HF admission or death, even after adjusting for LA volume and left ventricular remodeling.
Related Concept Videos
Magnetic Resonance Imaging
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Atomic Nuclei: Magnetic Resonance
Cardiac Catheterization III: Left Heart Catheterization
Prevalence and Incidence
Prevalence indicates the proportion of individuals in a population who have a specific disease or health...

