Left Atrial Phasic Function by Cardiac Magnetic Resonance Feature Tracking Is a Strong Predictor of Incident

Julio A Chirinos1,2,3, Mayank Sardana4, Bilal Ansari2

  • 1Department of Radiology, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia (J.A.C., G.O., R.M., S.G., S.R.A.).

Abstract

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
9.3K
Blood Studies for Cardiovascular System I: Cardiac Biomarkers01:20

Blood Studies for Cardiovascular System I: Cardiac Biomarkers

Cardiac biomarkers are enzymes, proteins, and hormones released into the blood when cardiac cells are injured. They are powerful tools for triaging.
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
857
Titration Calculations: Strong Acid - Strong Base02:28

Titration Calculations: Strong Acid - Strong Base

Calculating pH for Titration Solutions: Strong Acid/Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
33.9K
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
1.2K
Cardiac Catheterization III: Left Heart Catheterization01:24

Cardiac Catheterization III: Left Heart Catheterization

Left heart catheterization is an invasive diagnostic procedure used to evaluate the function and structure of the left side of the heart. It is generally performed to diagnose and treat cardiovascular conditions such as valve abnormalities, coronary artery disease, and congenital heart defects.Diagnostic and therapeutic purposesLeft heart catheterization serves various diagnostic and therapeutic purposes, including:Assessing coronary artery bypass grafts.Evaluating coronary artery disease in...
708
Prevalence and Incidence01:08

Prevalence and Incidence

In statistical epidemiology and health sciences, two essential metrics—prevalence and incidence—are fundamental for understanding disease dynamics within a population. These measures enable public health officials, epidemiologists, and researchers to assess the burden of diseases, allocate resources effectively, and design impactful public health policies and interventions.
Prevalence indicates the proportion of individuals in a population who have a specific disease or health...
1.8K