Ex Vivo Evaluation of the ArtVentive EOS Occlusion Device for the Management of Biliary Leaks
Purpose:
Percutaneous treatment of biliary leaks is frequently required, yet technically challenging and limited to smaller fistulas. This study sought to evaluate the off-the-shelf use of the ArtVentive EOS device for the occlusion of biliary or cystic stump leaks.
Materials And Methods:
ePTFE-covered ArtVentive EOS devices were used to perform biliary leak embolization in 5 explanted porcine livers and in 3 explanted bovine livers. After establishing standard percutaneous transhepatic biliary drainage access, artificially created biliary leaks were occluded using 5 & 8 mm EOS devices. Using the 5 mm device, peripheral (n = 3), central (n = 1) and cystic duct leaks (n = 1) were occluded. Using the 8 mm device, peripheral (n = 1), central (n = 1), main (n = 1) and cystic duct leaks (n = 2) were occluded. Total leak occlusion was controlled by cholangiography.
Results:
Selective deployment and occlusion of central biliary leaks (3/3) and cystic stump leaks (3/3) was successful in all cases. Peripheral leaks could not be selectively catheterized in 3 out of 4 cases, making device deployment several millimeters proximal to the leaks necessary.
Conclusion:
Selective occlusion of the cystic stump, central biliary, and larger peripheral biliary leaks using the EOS device is technically feasible ex-vivo in a single setting.
Key Points:
· Due to the impermeable ePTFE membrane, one EOS suffices to completely occlude biliary leaks.. · The EOS enables selective occlusion of central and larger peripheral biliary leaks.. · Smaller biliary leaks cannot be treated selectively with the EOS..
Citation Format:
· Kuetting D, Schild HH, Pieper CC. Ex Vivo Evaluation of the ArtVentive EOS Occlusion Device for the Management of Biliary Leaks. Fortschr Röntgenstr 2019; 191: 553 - 559.
More Related Videos
06:30Complete and Partial Resuscitative Endovascular Balloon Occlusion of the Aorta for Hemorrhagic Shock
Published on: May 19, 2022
10:45A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
Published on: January 22, 2018
Related Concept Videos
Tonsillitis II: Management
Non-ohmic Devices
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
Mnemonic Devices
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...
Impression Management Techniques I: Managing Appearances
Managing Impressions
Management of Insomnia