Related Experiment Video
Updated: Jan 31, 2026

Investigating von Willebrand Factor Pathophysiology Using a Flow Chamber Model of von Willebrand Factor-platelet String Formation
Published on: August 14, 2017
Defective collagen binding and increased bleeding in a murine model of von Willebrand disease affecting collagen IV
T L Slobodianuk1,2, C Kochelek1,2, J Foeckler3
1Blood Research Institute, BloodCenter of Wisconsin, Milwaukee, WI, USA.
Essentials Defective binding to collagen IV has been seen in von Willebrand factor (VWF) A1 domain variants. We developed a murine model of defective VWF-collagen IV interactions with VWF variant p.R1399H. p.1399HH homozygous mice had decreased binding to collagen IV and increased bleeding times. p.1399HH homozygous mice had increased time to thrombosis and decreased platelet adhesion. SUMMARY: Background von Willebrand factor (VWF) binding to type IV collagen occurs via the VWF A1 domain, with p.R1399H being the most common VWF variant affecting this interaction. Objectives We generated a murine model of 1399H VWF to investigate its in vivo effects. Methods Mice expressing the murine 1399H variant were generated via gene targeting in embryonic stem cells. VWF antigen and VWF collagen binding were measured with ELISA. Tail bleeding time assays were performed by clipping a 3-mm segment. Ferric chloride-induced thrombosis was measured via ultrasound in the carotid artery. Platelet aggregation in response to collagens I and IV was measured. VWF-dependent platelet adhesion to collagen IV was measured under flow. Results Breeding of heterozygous p.R1399H and homozygous p.1399HH mice was observed to follow normal Mendelian ratios. No spontaneous bleeding was observed for any of the offspring. VWF expression was normal, but VWF binding to collagen IV was decreased in both heterozygous and homozygous offspring. Blood loss following tail resection was increased for p.1399HH mice, and occlusion times following ferric chloride-induced thrombosis were prolonged. Platelet aggregation was unaffected, but platelet adhesion to collagen IV under flow was diminished for p.1399HH mice. Conclusions These results show that a decrease in the ability of 1399H VWF to bind collagen IV under static conditions corresponds to a decrease in binding under flow conditions, an increased bleeding time, and a prolonged time to thrombosis. This study supports the potential for a bleeding phenotype in patients with aberrant VWF-collagen IV binding.
Essentials Defective binding to collagen IV has been seen in von Willebrand factor (VWF) A1 domain variants. We developed a murine model of defective VWF-collagen IV interactions with VWF variant p.R1399H. p.1399HH homozygous mice had decreased binding to collagen IV and increased bleeding times. p.1399HH homozygous mice had increased time to thrombosis and decreased platelet adhesion. SUMMARY: Background von Willebrand factor (VWF) binding to type IV collagen occurs via the VWF A1 domain, with p.R1399H being the most common VWF variant affecting this interaction. Objectives We generated a murine model of 1399H VWF to investigate its in vivo effects. Methods Mice expressing the murine 1399H variant were generated via gene targeting in embryonic stem cells. VWF antigen and VWF collagen binding were measured with ELISA. Tail bleeding time assays were performed by clipping a 3-mm segment. Ferric chloride-induced thrombosis was measured via ultrasound in the carotid artery. Platelet aggregation in response to collagens I and IV was measured. VWF-dependent platelet adhesion to collagen IV was measured under flow. Results Breeding of heterozygous p.R1399H and homozygous p.1399HH mice was observed to follow normal Mendelian ratios. No spontaneous bleeding was observed for any of the offspring. VWF expression was normal, but VWF binding to collagen IV was decreased in both heterozygous and homozygous offspring. Blood loss following tail resection was increased for p.1399HH mice, and occlusion times following ferric chloride-induced thrombosis were prolonged. Platelet aggregation was unaffected, but platelet adhesion to collagen IV under flow was diminished for p.1399HH mice. Conclusions These results show that a decrease in the ability of 1399H VWF to bind collagen IV under static conditions corresponds to a decrease in binding under flow conditions, an increased bleeding time, and a prolonged time to thrombosis. This study supports the potential for a bleeding phenotype in patients with aberrant VWF-collagen IV binding.
More Related Videos
04:42Author Spotlight: Analyzing Fibrosis Development in Chronic Lung Allograft Rejection Using Picrosirius Red Staining in Mouse Models
Published on: March 21, 2025
07:03Imaging Denatured Collagen Strands In vivo and Ex vivo via Photo-triggered Hybridization of Caged Collagen Mimetic Peptides
Published on: January 31, 2014
Related Concept Videos
Type IV Collagen of Basal Lamina
A type IV collagen molecule has six alpha chains which can...
The Equilibrium Binding Constant and Binding Strength
The Equilibrium Binding Constant and Binding Strength
Nuclear Binding Energy
Fibril-associated Collagen
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...
Conserved Binding Sites
Binding sites are often located in large pockets, and if their location on a protein’s surface is unknown, it can be predicted using various approaches. The energetic method computationally...