Related Experiment Video
Updated: Jan 31, 2026

Monitoring Protein Adsorption with Solid-state Nanopores
Published on: December 2, 2011
Assessing the Thickness-Permeation Paradigm in Nanoporous Membranes
Jakob Buchheim1, Karl-Philipp Schlichting2, Roman M Wyss3
1Nanoscience for Energy Technology and Sustainability, Department of Mechanical and Process Engineering , Eidgenössische Technische Hochschule (ETH) Zürich , Tannenstrasse 3 , Zürich CH-8092 , Switzerland.
Abstract:
Driven by the need of maximizing performance, membrane nanofabrication strives for ever thinner materials aiming to increase permeation while evoking inherent challenges stemming from mechanical stability and defects. We investigate this thickness rationale by studying viscous transport mechanisms across nanopores when transitioning the membrane thickness from infinitely thin to finite values. We synthesize double-layer graphene membranes containing pores with diameters from ∼6 to 1000 nm to investigate liquid permeation over a wide range of viscosities and pressures. Nanoporous membranes with thicknesses up to 90 nm realized by atomic layer deposition demonstrate dominance of the entrance resistance for aspect ratios up to one. Liquid permeation across these atomically thin pores is limited by viscous dissipation at the pore entrance. Independent of thickness and universal for porous materials, this entrance resistance sets an upper bound to the viscous transport. Our results imply that membranes with near-ultimate permeation should feature rationally selected thicknesses based on the target solute size for applications ranging from osmosis to microfiltration and introduce a proper perspective to the pursuit of ever thinner membranes.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Design Example: Deciding Thickness of Lubricating Fluid in a Shaft
To calculate the required thickness of the lubricant layer, the tangential velocity at the shaft's surface must first be determined. This velocity is calculated by converting the rotational speed to angular velocity...
Introduction to Membrane Proteins
What are Membranes?
What are Membranes?
The Resting Membrane Potential

