[Improvement of Image Quality in the Axial Section Using High-resolution Scan Mode and Hybrid Iterative
Yuki Sakai1, Takashi Shirasaka1, Masatoshi Kondo1
1Division of Radiology, Department of Medical Technology, Kyushu University Hospital.
Abstract:
The purpose of this study is to compare the physical characteristics and visibility of high-resolution and conventional images acquired with the same X-ray dose, and to investigate the superiority of super high-resolution imaging. A Catphan phantom was scanned in the normal resolution (NR), high-resolution (HR), and super high-resolution (SHR) modes of ultra-high-resolution computed tomography at 120 kV and 75 mAs. All images were reconstructed into a 5-mm thick image slices with filtered back-projection (FBP) and hybrid image reconstruction (HIR), which included normal and enhanced adaptive iterative dose reduction 3D (AIDR and eAIDR, respectively). The modulation transfer function (MTF) and noise power spectrum (NPS) were measured using the circular edge method and radial frequency method, respectively. The signal-to-noise ratio (SNR) was then calculated. High-contrast resolution and low-contrast detectability were evaluated visually by five radiological technologists. The MTFs of HReAIDR and HRFBP images were higher than those of NRFBP images. However, the NPSs of HReAIDR and HRFBP images were larger than those of NRFBP images. The SNR of HReAIDR images was higher than that of NRFBP and HRFBP images. The scores of high-contrast resolution of HReAIDR, NRFBP, and HRFBP images were 13, 8, and 13 cycles/cm, respectively, and the scores of low-contrast detectability were 5, 5, and 6 mm, respectively. Hence, an improvement in high-contrast resolution of signal more than 400 HU in the axial section can be achieved without increasing the radiation dose and decreasing low-contrast detectability with 10 HU using the HR mode and eAIDR.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Super-resolution Fluorescence Microscopy
Racemic Mixtures and the Resolution of Enantiomers
High-Resolution Mass Spectrometry (HRMS)