Seed prioritized unwrapping (SPUN) for MR phase imaging
Related Experiment Video
Updated: Jan 31, 2026

Phase Contrast Magnetic Resonance Imaging in the Rat Common Carotid Artery
Published on: September 5, 2018
Yongquan Ye1, Fei Zhou2, Jinguang Zong3
1United Imaging of Healthcare America, Houston, Texas, USA.
Background:
Region-growing-based phase unwrapping methods have the potential for lossless phase aliasing removal, but generally suffer from unwrapping error propagation associated with discontinuous phase and/or long calculation times. The tradeoff point between robustness and efficiency of phase unwrapping methods in the region-growing category requires improvement.
Purpose:
To demonstrate an accurate, robust, and efficient region-growing phase unwrapping method for MR phase imaging applications.
Study Type:
Prospective. SUBJECTS, PHANTOM: normal human subjects (10) / brain surgery patients (2) / water phantoms / computer simulation.
Field Strength/Sequence:
3 T/gradient echo sequences (2D and 3D).
Assessment:
A seed prioritized unwrapping (SPUN) method was developed based on single-region growing, prioritizing only a portion (eg, 100 seeds or 1% seeds) of available seed voxels based on continuity quality during each region-growing iteration. Computer simulation, phantom, and in vivo brain and pelvis scans were performed. The error rates, seed percentages, and calculation times were recorded and reported. SPUN unwrapped phase images were visually evaluated and compared with Laplacian unwrapped results.
Statistical Tests:
Monte Carlo simulation was performed on a 3D dipole phase model with a signal-to-noise ratio (SNR) of 1-9 dB, to obtain the mean and standard deviation of calculation error rates and calculation times.
Results:
Simulation revealed a very robust unwrapping performance of SPUN, reaching an error rate of <0.4% even with SNR as low as 1 dB. For all in vivo data, SPUN was able to robustly unwrap the phase images of modest SNR and complex morphology with visually minimal errors and fast calculation speed (eg, <4 min for 368 × 312 × 128 data) when using a proper seed priority number, eg, Nsp = 1 or 10 voxels for 2D and Nsp = 1% for 3D data.
Data Conclusion:
SPUN offers very robust and fast region-growing-based phase unwrapping, and does not require any tissue masking or segmentation, nor poses a limitation over imaging parameters.
Level Of Evidence:
3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;50:62-70.
More Related Videos
Related Concept Videos
Seed Structure and Early Development of the Sporophyte
Phase Diagrams
Introduction to Seed Plants
Phase Transitions
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...
Capacitance: Single-Phase And Three-Phase Line
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...