The measurement of dorsal radial tilt by x-ray and computed tomography
Jingning Li1, Zhenjie Ma1, Fei Gao1
1Department of Hand Surgery, Yantaishan Hospital, Yantai, Shangdong, China.
Objective:
We conducted this study to define and measure the dorsal radial tilt, and to guide the reduction of distal radius fractures and the pre-bending of steel plates used in surgery.
Methods:
The dorsal radial tilt was measured using both computed tomography (CT) and x-ray from both left and right side. The differences and correlations of the data measured by those two methods and from two sides were analyzed.
Results:
The tilts measured by x-ray were significantly bigger than those measured by CT from the left side (t=55.51, p < 0.01) and from the right side (t=49.81, p < 0.01). The tilts measured by those two methods from the left and right sides were correlated (r=0.85, p < 0.01; r=0.81, p < 0.01). The dorsal radial tilts measured from the left side were not significantly different from those measured from the right side by CT (t=1.49, p > 0.05) and by x-ray (t=1.51, p > 0.05). The dorsal radial tilts measured from the left side by CT were significantly different from those measured from the right side by x-ray (t=43.07, p < 0.01), and these two sets of data were correlated (r=0.71, p < 0.01). The dorsal radial tilts measured from the left side by x-ray was significantly different from that measured from right side by CT (t=40.43, p < 0.01), and those two sets of data were also correlated (r=0.75, p < 0.01).
Conclusions:
The dorsal radial tilts measured from one side by one method can be used to estimate the tilts measured from the other side / the same side by the same method / the other method.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
X-ray Imaging