Related Experiment Video
Updated: Jan 31, 2026

A Mouse Model of Pulmonary Fibrosis Induced by Nasal Bleomycin Nebulization
Published on: January 20, 2023
Nasal high-flow bronchodilator nebulization: a randomized cross-over study
François Reminiac1,2,3, Laurent Vecellio2, Laetitia Bodet-Contentin1,4,5
1Médecine Intensive Réanimation, CHRU de Tours, 2, Bd Tonnellé, 37044, Tours Cedex 9, France.
Background:
There is an absence of controlled clinical data showing bronchodilation effectiveness after nebulization via nasal high-flow therapy circuits.
Results:
Twenty-five patients with reversible airflow obstruction received, in a randomized order: (1) 2.5 mg albuterol delivered via a jet nebulizer with a facial mask; (2) 2.5 mg albuterol delivered via a vibrating mesh nebulizer placed downstream of a nasal high-flow humidification chamber (30 L/min and 37 °C); and (3) nasal high-flow therapy without nebulization. All three conditions induced significant individual increases in forced expiratory volume in one second (FEV1) compared to baseline. The median change was similar after facial mask nebulization [+ 350 mL (+ 180; + 550); + 18% (+ 8; + 30)] and nasal high flow with nebulization [+ 330 mL (+ 140; + 390); + 16% (+ 5; + 24)], p = 0.11. However, it was significantly lower after nasal high-flow therapy without nebulization [+ 50 mL (- 10; + 220); + 3% (- 1; + 8)], p = 0.0009. FEV1 increases after facial mask and nasal high-flow nebulization as well as residual volume decreases were well correlated (p < 0.0001 and p = 0.01). Both techniques showed good agreement in terms of airflow obstruction reversibility (kappa 0.60).
Conclusion:
Albuterol vibrating mesh nebulization within a nasal high-flow circuit induces similar bronchodilation to standard facial mask jet nebulization. Beyond pharmacological bronchodilation, nasal high flow by itself may induce small but significant bronchodilation.
More Related Videos
07:28Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
15:04Modeling and Simulations of Olfactory Drug Delivery with Passive and Active Controls of Nasally Inhaled Pharmaceutical Aerosols
Published on: May 20, 2016
Related Concept Videos
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
COPD: Management Using Bronchodilators and Corticosteroids
Crossing Over
The homologous pairs of sister chromosomes—one from the maternal and one from the paternal genome—then begin to align alongside each other lengthwise, matching corresponding DNA positions in a process...
Cross-Sectional Research
Monohybrid Crosses
Random Error