Detection of Vesicoureteral Reflux Using Electrical Impedance Tomography

Summary

Electrical impedance tomography (EIT) noninvasively detects vesicoureteral reflux (VUR) in animal models with high accuracy. This promising method could be used for screening VUR in children, offering a safer alternative to current diagnostics.

Related Concept Videos

Impedance Combination01:21

Impedance Combination

Consider a string of christmas lights, each bulb symbolizing an impedance element. In this series configuration, the flow of electric current remains uniform across every component. This behavior aligns with Kirchhoff's Voltage Law (KVL), which asserts that the total impedance in such a setup equals the sum of individual impedances—akin to resistors in series. It follows that the voltage from the power source is distributed proportionally among these components, adhering to the voltage...
752
Impedances and Admittance01:23

Impedances and Admittance

In the realm of AC circuits, passive circuit elements like resistors, inductors, and capacitors take on a different character when characterized by phasor voltage and current. Their behavior is expressed through impedance, a vital concept in AC circuit analysis.
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
1.9K
Gastroesophageal Reflux Disease I: Meaning and Pathophysiology01:29

Gastroesophageal Reflux Disease I: Meaning and Pathophysiology

Gastroesophageal Reflux Disease (GERD) involves the recurrent backflow of the stomach or duodenal contents into the esophagus, leading to troublesome symptoms and potential esophageal mucosal damage. Although GERD is often referred to as a disease, it is more accurately described as a syndrome, as it encompasses a range of symptoms and complications rather than a singular pathological entity, impacting a large number of individuals as the most prevalent upper gastrointestinal problem. Roughly...
1.6K
Series Impedances: Three-Phase Line01:27

Series Impedances: Three-Phase Line

Calculating series impedances for a three-phase overhead line involves evaluating resistances and inductive reactances in a network with three-phase and multiple neutral conductors grounded at regular intervals.
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
445
Bus Impedance Matrix01:24

Bus Impedance Matrix

Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
529
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
454