Essential considerations for accurate evaluation of photoneutron contamination in Radiotherapy
Amir Hossein Karimi1, Hrvoje Brkić2, Daryoush Shahbazi-Gahrouei3
1Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
Abstract:
Nowadays, high-energy X-rays produced by medical linear accelerators (LINACs) are widely used in many Radiation Therapy (RT) centers. High-energy photons (> 8 MeV) produce undesired neutrons in the LINAC head which raise concerns about unwanted neutron dose to the patients and RT personnel. Regarding the significance of radiation protection in RT, it is important to evaluate photoneutron contamination inside the RT room. Unfortunately, neutron dosimeters used for this purpose have limitations that can under the best conditions cause to > 10% uncertainty. In addition to this uncertainty, the present Monte Carlo (MC) study introduces another uncertainty in measurements (nearly up to 20%) when neutron ambient dose equivalent (Hn*(10)) is measured at the patient table or inside the maze and the change in neutron energy is ignored. This type of uncertainty can even reach 35% if Hn*(10) is measured by dosimeters covered by a layer of 10B as converter. So, in these cases, neglecting the change in neutron energy can threaten the credibility of measured data and one should attend to this energy change in order to reduce measurement uncertainty to the possible minimum. This study also discusses the change in neutron spectra and Hn*(10) at the patient table caused by removing a typical RT room from MC simulations. Under such conditions, neutron mean energy (Ēn) overestimated by 0.2-0.4 MeV at the patient table. Neutron fluence (φn) at the isocenter (IC) was underestimated by 23-54% for different field sizes that caused Hn*(10) to be miscalculated up to 24%. This finding informs researchers that for accurate evaluation of Hn*(10) at the patient table, simulating the RT room is an effective parameter in MC studies.
More Related Videos
11:26Ecotoxicological Method with Marine Bacteria Vibrio anguillarum to Evaluate the Acute Toxicity of Environmental Contaminants
Published on: May 26, 2017
11:24Stem Cell Transplantation Strategies for the Restoration of Cognitive Dysfunction Caused by Cranial Radiotherapy
Published on: October 18, 2011
Related Concept Videos
Compounds Essential to Human Function
Inorganic Compounds Essential to Human Functioning
Inorganic compounds essential to human functioning include water, salts, acids, and bases. These compounds are inorganic, i.e., they do not have a carbon-hydrogen bond. Water...
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Essential Minerals for Bone Health
Calcium and Phosphorus
Calcium is a critical component of bones, especially in the form of calcium phosphate and calcium carbonate. Since the body cannot make calcium, it must be obtained from the diet. However, calcium cannot be absorbed from the small intestine without...
Design Consideration
The factor of safety is another key...
Self-Evaluation: Self-Enhancement and Self-Verification
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...