Related Experiment Video
Updated: Jan 31, 2026

Development of a Neonatal Piglet Acute Lung Injury Model Recreating the Early Environment of Preterm Infant Lungs
Published on: October 31, 2025
Research and development of safety management information system for neonatal bathroom and its clinical application:
Fang Wang1, Si-Yu Zhang2, Jian-Rong Chen3
1Department of Gynecology and Obstetrics.
We developed a bathroom safety management information system to decrease adverse nursing events, and observed the application of the self-developed safety management information system in neonatal bathroom.A total of 3482 newborns receiving neonatal bath and rooming in between May 2015 and May 2017, were enrolled in this study. Of the 3482 newborns, 1727 that did not use the safety management information system from May 1, 2015 to May 31, 2016, were considered as control group; and other 1755 that used the safety management information system from June 1, 2016 to May 31, 2017 were entered in observation group. The accident rate of adverse nursing events, the duration to check wristbands, response time of urgency call, quantitative data recording for nursing procedures, and pregnant women's and their families' satisfaction degree were compared between the 2 groups.The management information system possesses 4 functions including personal identification, nursing operation quantification, monitoring alarm and music function, and guidance on specialized knowledge and skills. The accident rate of adverse nursing events was significantly lower in the observation than in the control group (P < .05). The duration to check wristbands and the response time of urgency call were all significantly shorter in the observation group than in the control group (all P < .05). Quantitative data recording was significantly better in the observation than in the control group (P < .05). Satisfaction degree was significantly higher in the observation group (96.47%) than in the control group (89.69%) (P < .05). The wireless transmission information was exact and safe, and the system was sensitive and reliable.The system not only is clinically practical but also can enhance the safety of newborns and improve pregnant women's and their families' satisfaction degree.
We developed a bathroom safety management information system to decrease adverse nursing events, and observed the application of the self-developed safety management information system in neonatal bathroom.A total of 3482 newborns receiving neonatal bath and rooming in between May 2015 and May 2017, were enrolled in this study. Of the 3482 newborns, 1727 that did not use the safety management information system from May 1, 2015 to May 31, 2016, were considered as control group; and other 1755 that used the safety management information system from June 1, 2016 to May 31, 2017 were entered in observation group. The accident rate of adverse nursing events, the duration to check wristbands, response time of urgency call, quantitative data recording for nursing procedures, and pregnant women's and their families' satisfaction degree were compared between the 2 groups.The management information system possesses 4 functions including personal identification, nursing operation quantification, monitoring alarm and music function, and guidance on specialized knowledge and skills. The accident rate of adverse nursing events was significantly lower in the observation than in the control group (P < .05). The duration to check wristbands and the response time of urgency call were all significantly shorter in the observation group than in the control group (all P < .05). Quantitative data recording was significantly better in the observation than in the control group (P < .05). Satisfaction degree was significantly higher in the observation group (96.47%) than in the control group (89.69%) (P < .05). The wireless transmission information was exact and safe, and the system was sensitive and reliable.The system not only is clinically practical but also can enhance the safety of newborns and improve pregnant women's and their families' satisfaction degree.
Related Concept Videos
Esophageal Perforation-II: Clinical Manifestations and Management
Clinical Manifestations:
Barrett Esophagus-II: Clinical Manifestations and Management
To diagnose Barrett's esophagus, healthcare providers often recommend an endoscopy for those showing symptoms of acid reflux. The procedure...
Esophageal Varices-II: Clinical Features and Management
In the initial assessment, a thorough review of the patient's medical history is vital to identify risk factors such as liver disease, alcohol...
Gastritis III: Clinical Manifestations and Management
Clinical manifestations of acute gastritis
The patient with acute gastritis may have a rapid onset of symptoms, such as epigastric pain or discomfort, dyspepsia, anorexia, hiccups, or nausea and vomiting, which can last from a few hours to a few days. Erosive or hemorrhagic gastritis may cause bleeding, which may manifest as blood in vomit or as...
Esophageal Strictures-II: Clinical Features and Management
Healthcare providers should gather a comprehensive medical history and conduct a physical examination for diagnosis. If esophageal stricture is...
Acute Pancreatitis II: Clinical Manifestations and Management

