Comparison of Imaging Softwares for Upper Airway Evaluation: Preliminary Study
Guilherme Dos Santos Trento1, Lucas Borin Moura1, Rubens Spin-Neto2
1Department of Diagnosis and Surgery, Dental School of Araraquara, São Paulo State University, Araraquara, São Paulo, Brazil.
Two software packages, Mimics and Dolphin, show comparable accuracy for upper airway volume measurements using cone beam computed tomography scans. This finding aids in selecting reliable tools for airway analysis.
Area of Science:
- Dentistry
- Radiology
- Medical Imaging
Background:
- Growing interest in upper airway evaluation necessitates efficient analysis tools.
- Software development aims to improve the accuracy and precision of airway volume measurements.
- Cone beam computed tomography (CBCT) is a key imaging modality for airway assessment.
Purpose of the Study:
- To compare the accuracy and precision of Mimics and Dolphin software for upper airway space measurements.
- To evaluate the reliability of these software packages in quantifying airway volume.
Main Methods:
- Nine patients undergoing surgically assisted rapid maxillary expansion provided preoperative CBCT scans.
- DICOM files were imported into Mimics and Dolphin software for analysis.
- Upper airway volume was measured using both software packages.
Main Results:
- The mean upper airway volume in the Dolphin group (G1) was 10.791 cm³ (SD = 4.269 cm³).
- The mean upper airway volume in the Mimics group (G2) was 10.553 cm³ (SD = 4.564 cm³).
- No statistically significant difference was found between the volume measurements of the two software packages (p = 0.105).
Conclusions:
- Mimics and Dolphin software demonstrate comparable performance in measuring upper airway volume.
- Both software packages are reliable tools for upper airway space analysis in patients undergoing orthodontic treatment.
- The choice between Mimics and Dolphin may not significantly impact the accuracy of airway volume quantification.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Arteries of the Upper Limbs
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Veins of Upper Limbs
The deep venous system is primarily composed of the ulnar and radial veins. The ulnar vein, which drains the fingers through the superficial palmar venous arches, and the radial vein, which serves the palms via the deep palmar...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...