A comparison of the new ROTEM® sigma with its predecessor, the ROTEMdelta
B Schenk1, K Görlinger2,3, B Treml1
1Department of General and Surgical Intensive Care Medicine, Medical University of Innsbruck, Austria.
Thromboelastometry point-of-care coagulation testing facilitates optimised management of bleeding. Previous thromboelastometry systems required the blood sample and liquid reagents to be pipetted in several manual steps by trained personnel. The ROTEMsigma coagulation analyser is a fully automated point-of-care device. We aimed to assess the reference ranges of the new device and to compare the results with those of the predecessor device, the ROTEMdelta. We took blood from healthy volunteers and from hyper- or hypocoagulable patients; blood samples from healthy volunteers served to determine reference ranges for the most important parameters for the ROTEMsigma: CTEXTEM 48-61 s; A5EXTEM 30-51 mm; MCFEXTEM 54-70 mm; CTINTEM 138-174 s; MCFINTEM 51-67 mm and MCFFIBTEM 5-24 mm. We then used blood samples from patients to compare the results obtained between the old and the new device. We found a strong correlation between the same tests performed on two ROTEMsigma devices and between the ROTEMsigma and the ROTEMdelta with respect to the determination of thromboelastometry parameters of hyper- and hypocoagulable patients (all p < 0.001 and R > 0.8). Performance evaluation for the ROTEMsigma device showed very high precision (R > 0.99, p < 0.001). Our reference ranges can serve as an important aid for other hospitals using this new device.
Thromboelastometry point-of-care coagulation testing facilitates optimised management of bleeding. Previous thromboelastometry systems required the blood sample and liquid reagents to be pipetted in several manual steps by trained personnel. The ROTEMsigma coagulation analyser is a fully automated point-of-care device. We aimed to assess the reference ranges of the new device and to compare the results with those of the predecessor device, the ROTEMdelta. We took blood from healthy volunteers and from hyper- or hypocoagulable patients; blood samples from healthy volunteers served to determine reference ranges for the most important parameters for the ROTEMsigma: CTEXTEM 48-61 s; A5EXTEM 30-51 mm; MCFEXTEM 54-70 mm; CTINTEM 138-174 s; MCFINTEM 51-67 mm and MCFFIBTEM 5-24 mm. We then used blood samples from patients to compare the results obtained between the old and the new device. We found a strong correlation between the same tests performed on two ROTEMsigma devices and between the ROTEMsigma and the ROTEMdelta with respect to the determination of thromboelastometry parameters of hyper- and hypocoagulable patients (all p < 0.001 and R > 0.8). Performance evaluation for the ROTEMsigma device showed very high precision (R > 0.99, p < 0.001). Our reference ranges can serve as an important aid for other hospitals using this new device.
More Related Videos
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Comparison between RL and RC circuits
Molecular Comparison of Gases, Liquids, and Solids