Intra- and interreader reproducibility of PI-RADSv2: A multireader study
Clayton P Smith1,2, Stephanie A Harmon3, Tristan Barrett4
1Molecular Imaging Program, National Cancer Institute, NIH, Bethesda, Maryland, USA.
The Prostate Imaging Reporting and Data System version 2 (PI-RADSv2) shows moderate intrareader but poor interreader reproducibility for prostate MRI lesion assessment. Standardized training is needed to improve consistency in PI-RADSv2 scoring.
Area of Science:
- Radiology
- Oncology
- Medical Imaging
Background:
- The Prostate Imaging Reporting and Data System version 2 (PI-RADSv2) is widely used for prostate MRI since 2015.
- While interreader reproducibility has been examined, intrareader reproducibility of PI-RADSv2 remains understudied.
Purpose of the Study:
- To assess the intra- and interreader reproducibility of PI-RADSv2 in evaluating intraprostatic lesions using multiparametric MRI (mpMRI).
Main Methods:
- Retrospective analysis of 102 biopsy-naïve patients undergoing prostate mpMRI (3T).
- Four readers from different institutions scored lesions twice (4-week interval) using PI-RADSv2.
- Reproducibility quantified using Kappa (κ) statistics, specific agreement (Po), and intraclass correlation coefficient (ICC) for measurements.
Main Results:
- Moderate intrareader reproducibility (κ=0.43-0.67) and substantial agreement (Po=0.60-0.77) were observed.
- Poor to moderate interreader reproducibility (κ=0.24, Po=0.46) was found.
- Experienced readers demonstrated better interreader agreement than intermediate readers.
- Intrareader ICC for lesion measurement was 0.82, while interreader ICC was 0.71.
Conclusions:
- PI-RADSv2 demonstrates moderate intrareader and poor interreader reproducibility for prostate MRI lesion scoring.
- Moderate interreader reproducibility was noted for lesion measurements.
- Findings highlight the need for enhanced, standardized reader training to improve PI-RADSv2 consistency.
Related Concept Videos
PI Controller: Design
The Buckingham Pi Theorem
Determination of Pi Terms
The theorem indicates that the...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Case Studies
Imaging Studies I: Kidney, Ureter, and Bladder Studies