Related Experiment Video
Updated: Jan 31, 2026

Simultaneous Laryngopharyngeal and Conventional Esophageal pH Monitoring
Published on: December 14, 2020
Baseline Impedance Measured During High-resolution Esophageal Impedance Manometry in Patients With Rumination
Magnus Halland1, Karthik Ravi1, Holly A Nelson1
1Department of Gastroenterology and Hepatology, Mayo Clinic, Rochester MN.
Goals And Background:
Baseline impedance measured during high-resolution impedance manometry (HRIM) can distinguish patients with gastroesophageal reflux disease (GERD) from controls, presumably due to differences in esophageal acid exposure. The characteristics of regurgitation and reflux in rumination syndrome and GERD are very different, and thus we investigated whether baseline esophageal impedance would differ in these 2 patient groups compared with controls.
Study:
We compared 20 patients with rumination syndrome with 20 patients who had GERD and 40 controls. Baseline impedance was measured over 15 seconds during the landmark period of HRIM in all 18 impedance sensors on a HRIM catheter.
Results:
The mean distal baseline impedance measured in ohms during HRIM was 1336 Ω [95% confidence interval (CI)=799, 1873) in patients with GERD, 1536 Ω in rumination syndrome (95% CI=1012, 2061), and 3379 Ω in controls (95% CI=2999, 3759) (P<0.0001). Proximal impedance was significantly lower in the GERD and rumination groups compared with controls; rumination syndrome (2026; 95% CI=1493, 2559 Ω), GERD (2572; 95% CI=2027, 3118 Ω), and controls (3412; 95% CI=3026, 3798 Ω) (P<0.001).
Conclusions:
Baseline impedance measured during HRIM in patients with rumination syndrome is significantly lower than controls and appears similar to patients with GERD both in the proximal and distal esophagus. These findings suggest that the postprandial regurgitation in rumination syndrome alters both the distal and proximal esophageal mucosal barrier.
More Related Videos
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
07:44Author Spotlight: Implementation of BIVA for Analyzing Disease Risk Factors in Patients with Low Body Cell Mass
Published on: July 14, 2023
Related Concept Videos
Impedance Combination
Impedances and Admittance
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
Series Impedances: Three-Phase Line
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
RLC Series Circuits: Impedance
Thus, the magnitude of the impedance is given by the following equation,