Implementation of a Real-Time Psychosis Risk Detection and Alerting System Based on Electronic Health Records using CogStack
Published on: May 15, 2020
Using Calibration to Reduce Measurement Error in Prevalence Estimates Based on Electronic Health Records
Pui Ying Chan1,2, Yihong Zhao3, Sungwoo Lim1
1Division of Epidemiology, New York City Department of Health and Mental Hygiene, Long Island City, New York.
Introduction:
Increasing adoption of electronic health record (EHR) systems by health care providers presents an opportunity for EHR-based population health surveillance. EHR data, however, may be subject to measurement error because of factors such as data entry errors and lack of documentation by physicians. We investigated the use of a calibration model to reduce bias of prevalence estimates from the New York City (NYC) Macroscope, an EHR-based surveillance system.
Methods:
We calibrated 6 health indicators to the 2013-2014 NYC Health and Nutrition Examination Survey (NYC HANES) data: hypertension, diabetes, smoking, obesity, influenza vaccination, and depression. We classified indicators into having low measurement error or high measurement error on the basis of whether the proportion of misclassification (ie, false-negative or false-positive cases) was greater than 15% in 190 reviewed charts. We compared bias (ie, absolute difference between NYC Macroscope estimates and NYC HANES estimates) before and after calibration.
Results:
The health indicators with low measurement error had the same bias after calibration as before calibration (diabetes, 2.5 percentage points; smoking, 2.5 percentage points; obesity, 3.5 percentage points; hypertension, 1.1 percentage points). For indicators with high measurement error, bias decreased from 10.8 to 2.5 percentage points for depression, and from 26.7 to 8.4 percentage points for influenza vaccination.
Conclusion:
The calibration model has the potential to reduce bias of prevalence estimates from EHR-based surveillance systems for indicators with high measurement errors. Further research is warranted to assess the utility of the current calibration model for other EHR data and additional indicators.
Related Concept Videos
Purpose of Health Records I
Here's a breakdown of how health records serve these purposes:
Purpose of Health Records II
Prevalence and Incidence
Prevalence indicates the proportion of individuals in a population who have a specific disease or health...
Fundamental Attribution Error
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...